S'abonner

Comparison of the friction forces delivered by different elastomeric patterns and metal ligature on conventional metal brackets with a NiTi arch wire versus a self-ligating system: An in vitro study - 15/06/22

Doi : 10.1016/j.ortho.2022.100633 
Mateus Pieroni 1, Analia Gabriella Borges Ferraz Facury 2, Milton Santamaria-Jr 1, Américo Bortolazzo Correr 2, Lourenço Correr-Sobrinho 2, Mario Vedovello Filho 1, Ana Rosa Costa 1, José Guilherme Neves 1, 2,
1 Department of Orthodontics, Herminio Ometto Foundation, Araras, SP, Brazil 
2 Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, Piracicaba, SP, Brazil 

José Guilherme Neves, Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, Av. Limeira, 901–Arei o, Piracicaba 13414-903, Brazil.Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental SchoolAv. Limeira, 901–Arei oPiracicaba13414-903Brazil

Summary

Objectives

The aim of this study was to measure the frictional resistance of different types of ligatures used on conventional and self-ligating brackets.

Materials and methods

Monoblock (conventional) and Portia (self-ligating) brackets were used and the archwire used was nickel-titanium. On conventional brackets the ligatures tested were the Elastomeric type and steel 0.30 tie-wire. The groups were divided according to the ligature types (n=8): (1) conventional elastomeric ligature; (2) relaxed conventional elastomeric ligature; (3) elastomeric ligature in shape-8; (4) double vertical elastomeric ligatures; (5) double-crossed elastomeric ligatures; (6) crossed ligature; (7) steel wire ligature; and (8) self-ligating ligature (self-ligating bracket). A segment of five brackets, each ligature types, was mounted. The archwire, between the bracket and the ligature, was connected on Instron® Universal test machine to simulate the frictional resistance. The maximum frictional resistance was obtained, and the mean values were submitted to the analysis of variance (ANOVA) and the Tukey's post-hoc test (α=0.05).

Results

The elastomeric ligature in shape-8 showed the highest value compared with other groups (P<0.05). Although the crossed elastomeric ligature presented the lowest mean value and it was not statistically different regarding relaxed conventional elastomeric ligature, steel wire ligature and self-ligating (P0.05).

Conclusions

The frictional resistance was influenced by ligature types. Elastomeric Ligature in shape-8 showed the highest frictional force. Crossed Elastomeric Ligature had the lowest frictional force value.

Le texte complet de cet article est disponible en PDF.

Keywords : Orthodontic wires, Orthodontic brackets, Friction, Elastomers, Elastomeric ligature, Stainless steel ligature, Self-ligating brackets


Plan


© 2022  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 2

Article 100633- juin 2022 Retour au numéro
Article précédent Article précédent
  • Parental perception of malocclusion, its severity and aesthetic concerns in children with mixed dentition: A cross-sectional study
  • Felipe A. de Souza, Diego Patrik A. Carneiro, Marcelo de C. Meneghim, Silvia A.S. Vedovello
| Article suivant Article suivant
  • Shear bond strength of metallic orthodontic brackets to zirconium crowns treated by sandblasting compared to enamel using a universal adhesive: An in vitro study
  • Fatemeh Namvar, Mansoure Zarmehi Shahrebabak, Sepideh Arab, Maryam Abdoh Tabrizi, Amir Ghasemi, Fatemeh Safari

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.