S'abonner

Variability in rod to bone distance needed in pelvic subcutaneous internal fixation to avoid nerve compression: A tridimensional population-based study - 12/06/22

Doi : 10.1016/j.otsr.2022.103273 
Kevin Perry a, Brad Chauvin a, Drayton Daily a, Clarence J. Kee a, Massimo Max Morandi a, R. Shane Barton a, Patrick O‘Neal b, Bryan Saffell b, Cole Dewitt b, Luke Cranford b, Giovanni F. Solitro a,
a Department of Orthopaedic Surgery, Louisiana State University Health Science Center–Shreveport, Shreveport LA, United States 
b Department of Engineering and Science, Louisiana Tech University, Shreveport LA, United States 

Corresponding author at: Department of Orthopaedic Surgery, LSUHSC–Shreveport, 1501, Kings Highway, 71130 Shreveport LA, United States.Department of Orthopaedic Surgery, LSUHSC–Shreveport1501, Kings HighwayShreveport LA71130United States

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Pelvic internal fixation has become a popular method for treatment of unstable pelvic ring injuries. Although successful, one complication is femoral nerve palsy from compression of the connecting rod. In light of this complication, this study was designed to evaluate sagittal inclinations of the rod and the feasibility of using a rod with a constant curvature.

Hypothesis

It is hypothesized that that there is a connection between the sagittal inclination of the rod and the rod to bone distance, as well as single rod can be contoured with a constant curvature to be used in the majority of all patients.

Methods

Three dimensional models of pelvis CTs from a single level 1 trauma center were created and imported into a program where software superimposed a pre-contoured rod in the sagittal planes upon the pelvic slices. The sagittal inclination was deemed acceptable is no interference occurred between the area of compression risk and the rod. For each pelvis and considered sagittal rod inclination, the rod radius of curvature (ROC), minimal rod to bone distance (RTB) and transverse inclinations (φL and φR) were measured at which the pedicle screws should be inserted to follow the direction of the smallest RTB.

Results

The sagittal inclinations feasible for all subjects were between 15° to 30°. In this sagittal range, the average RTB varied in values ranging from 4.0±0.9mm to 25.4±11.4mm (p<0.01). Only 46% of subjects allowed a rod with constant curvature.

Discussion and Conclusion

Our study found that a rod to bone distance of 15mm was not safe for all models. As well, many subject models did not allow placement of pre-contoured rod. Patient specific templating of pelvic subcutaneous internal fixation is strictly needed to limit complications.

Level of evidence

VII; Basic Science.

Le texte complet de cet article est disponible en PDF.

Keywords : Pelvic subcutaneous internal fixation, Pelvic ring injuries, Internal fixation, Rod, Femoral nerve, Lateral femoral cutaneous nerve


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 4

Article 103273- juin 2022 Retour au numéro
Article précédent Article précédent
  • Arthroscopic treatment of type I and II greater trochanteric pain syndrome
  • Hichem Abid, Constant Foissey, Ibrahim Haidar, Benoît de Saint Vincent, Mathieu Thaunat
| Article suivant Article suivant
  • Pararectus approach vs. Stoppa approach for the treatment of acetabular fractures – a comparison of approach-related complications and operative outcome parameters from the German Pelvic Registry
  • Markus A. Küper, Björn Röhm, Christof Audretsch, Ulrich Stöckle, Andreas Höch, Tina Histing, Fabian M. Stuby, Alexander Trulson, Steven C. Herath, Working Group on Pelvic Fractures of the German Trauma Society

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.