S'abonner

Clinical results and radiological bony adaptations on a cementless short-stem prosthesis – A comparative study between anatomical and reverse total shoulder arthroplasty - 15/05/22

Doi : 10.1016/j.otsr.2022.103262 
Waleed Abduh a, Julien Berhouet b, , Ramy Samargandi b, Luc Favard b
a Department of Orthopedic, King Fahad General Hospital, Almadinah Almunawwarah, Saudi Arabia 
b Orthopedic surgery and traumatology department, universitary hospital Trousseau of Tours, avenue de la République, 37170 Chambray-lès-Tours, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Although the use of short stem and stemless shoulder prosthesis is trending, the surgical outcome may vary due to varying biomechanics. Objectives were to evaluate and compare the short-term clinical results and radiological changes between anatomical total shoulder arthroplasty (TSA) and reverse TSA (rTSA) with a short-stem humeral design.

Hypothesis

There is no clinical and radiological difference between TSA and rTSA using a short-stem humeral design.

Methods

This retrospective study included 66 patients who underwent TSA and rTSA (33 patients each) with a minimum 2-year follow-up. Radiographic findings, including preoperative Tingart cortical index (TCI), postoperative filling ratios of metaphysis (FRmet) and diaphysis (FRdia), bone adaptations, and osteolysis around the humeral stem at the immediate postoperative period, and the most recent follow-up were measured. Pre and postoperative Constant-Murley score, subjective shoulder value (SSV), and complications were noted.

Results

At a mean follow-up of 27 (range 24–50) months, FRmet was significantly higher in rTSA group than the TSA group (0.65 vs. 0.60, p=0.009). Bone resorption was similar in both groups (p=0.76) and was correlated to a lower TCI value of<2.9mm (p=0.02). Despite significant clinical improvement in individual groups, the comparison between groups was non-significant (p>0.05). Negative correlation was observed between TCI and total clinical score (p=0.045) in TSA group, active external rotation (p=0.019), activity (p=0.005), SSV (p=0.008) and total score (p=0.025) in rTSA group. Radiographic changes were not influenced by patient characteristics and clinical results (p>0.05).

Conclusion

Although no radiographic difference was observed between TSA and rTSA, better short-term clinical results observed with the usage of the short-stem humeral design prosthesis are encouraging.

Level of evidence

III; Retrospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Short stem prosthesis, Cementless fixation, Shoulder prosthesis, Humeral filling ratio, Humeral platform system


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 3

Article 103262- mai 2022 Retour au numéro
Article précédent Article précédent
  • Arthroplasty for weight-bearing shoulders
  • Léo Chiche, Jacques Teissier, Anthony Gelis, Michel Chammas, Isabelle Laffont, Bertrand Coulet
| Article suivant Article suivant
  • Assessment of intraoperative bleeding in reverse shoulder arthroplasty – with or without a stem
  • Fiona Sakek, Harrison Haight, Pierre Tuphé, Inès Regas, Antoine Adam, Séverin Rochet, Tristan Lascar, Laurent Obert, François Loisel

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.