S'abonner

Effect of maternal body mass index on the prophylactic dose of phenylephrine for preventing hypotension in parturients after spinal anaesthesia - 04/05/22

Doi : 10.1016/j.accpm.2022.101035 
Chen Yang a, Qiuyu Meng a, Yan Cheng a, Shaoqiang Huang a, , Xinhua Yu b
a Department of Anaesthesia, Obstetrics & Gynaecology Hospital, Fudan University, Shanghai, China 
b Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, University of Memphis, Memphis, TN, USA 

Corresponding author at: Shaoqiang Huang 128# Shenyang road, Shanghai 200090, China.Shaoqiang Huang 128# Shenyang roadShanghai200090China

Abstract

Background

To compare the median effective dose (ED50) of phenylephrine for prophylactic continuous infusion in parturients with different body mass indices (BMIs) during combined spinal-epidural anaesthesia for caesarean section and to investigate the impact of maternal BMI on the prophylactic dose of phenylephrine.

Methods

Parturients receiving combined spinal-epidural anaesthesia for elective caesarean section were divided into a standard group (Group S, BMI < 30 kg/m2) and an obesity group (Group O, BMI > 30 kg/m2), each with 30 patients. A sequential allocation design was used to administer the prophylactic infusion of phenylephrine after the completion of a spinal anaesthetic injection to prevent hypotension (defined as a reduction of systolic blood pressure ≥ 20% of the baseline value or systolic blood pressure < 90 mmHg), with an initial infusion rate of 50 μg/min for the first parturient subsequent adjusted up or down by 10 μg/min depending on whether the previous parturient developed hypotension or not during the study period. The Dixon and Massey method and the isotonic regression method were used to calculate and compare the ED50 and 95% confidence interval (CI) of phenylephrine between the two groups.

Results

The results were 21.92 μg/min (95% CI, 14.90–28.94 μg/min) for Group S and 42.14 μg/min (95% CI, 24.58–59.70 μg/min) for Group O. The ratio of relative potency of Group O to Group S is 1.92 (95% CI 1.09–3.14), P = 0.034.

Conclusions

The dose of phenylephrine for the prevention of hypotension after spinal anaesthesia for caesarean section is dependent on maternal BMI. Therefore, a weight-based phenylephrine dose is reasonable.

Le texte complet de cet article est disponible en PDF.

Keywords : Phenylephrine, Body mass indices, Hypotension, Spinal anaesthesia, Caesarean section


Plan


 This trial is registered at www.chictr.org.cn: Registration no. ChiCTR2000029705; principal investigator, Yangchen; date of registration, 1st of May 2020.


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 41 - N° 2

Article 101035- avril 2022 Retour au numéro
Article précédent Article précédent
  • Effects of labour analgesia with different concentrations of ropivacaine on maternal body temperature and inflammatory factor: A randomised controlled study
  • Xiubin Chen, Yueqi Zhang, Xiu Ni, Zhiqiang Liu
| Article suivant Article suivant
  • Femoral nerve inguinal approach versus proximal femoral triangle ap proach for continuous regional analgesia in active rehabilitation after total knee arthroplasty: A prospective, randomised study
  • Jérôme Guilley, Isabelle Besançon, Antoine Hivert, Anne Marine Plouhinec, Mathieu Oudot, Guillaume Venet, Nicolas Fraquet, Julien Cousin, Lucie Planche, Catherine Ganière, Alexis Duchalais

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.