S'abonner

Iliosacral screw fixation of pelvic ring disruption with tridimensional patient-specific template guidance - 13/04/22

Doi : 10.1016/j.otsr.2022.103210 
Feng Liu a, 1, Junyi Yu b, 1, Hongqi Yang a, Lihong Cai c, Li Chen a, Qing Lei a, 2, Pengfei Lei b, , 2
a Department of Orthopedics, The 3rd Hospital of Changsha, Hunan, P.R. China 
b Department of Orthopedics, Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital Central South University, 87 Xiangya Road, Changsha, Hunan, 410007, P.R. China 
c Department of Radiology, the 3rd Hospital of Changsha, 3D Printing Institute for Medical Application of Changsha, P.R. China 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Posterior pelvic ring disruption includes sacral fractures, sacroiliac joint fracture dislocations and ilium fractures. Percutaneous iliosacral screw fixation of sacral fractures and sacraoiliac joint fracture dislocations have been prevailing, it has the advantages of minimal invasiveness, less blood loss and low wound infection rate.

Hypothesis

This study was to evaluate the application of three-dimensional (3D) printed patient-specific guide template in closed reduction and iliosacral screw fixation of posterior pelvic ring disruption.

Material and methods

The data of patients, who were treated with closed reduction and iliosacral screw fixation of posterior pelvic ring disruption with the assistance of 3D printed guide template from December 2014 to September 2018, were collected. The screw placement time, fluoroscopy time, intraoperative blood loss, fracture reduction, screw position, and functional assessment were recorded.

Results

There were 17 cases of unstable pelvic fractures,and 20 screws were inserted for fixation of sacral fractures or sacroiliac joint dislocations, with bilateral screw placement in 3 cases. The average time for each screw placement was 45.9±8.6min (30–60min). The average fluoroscopy time for each screw insertion was 50.3±19.7s (24–96 s). The mean blood loss for each screw placement was 32.0±11.1ml (20–50ml). According to Matta scale, the fracture reduction was graded as excellent in all the 17 cases. According to the modified Gras classification, the 3D CT reconstruction of the pelvis demonstrated Grade 1 for 18 screws and Grade 2 for 2 screw. Functional outcome 1 year postoperatively was rated as 15 excellent and 2 good, according to the Majeed functional scale.

Discussion

It is feasible and safe to stabilize the posterior pelvic ring disruption using iliosacral screw fixation under assistance of the 3D printed guide template. It could reduce fluoroscopy time, screw placement time and intraoperative blood loss and achieve good postoperative recovery.

Level of proof

IV; Retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Three dimensional printing technique, Guide template, Unstable pelvic fracture, Stabilization


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 2

Article 103210- avril 2022 Retour au numéro
Article précédent Article précédent
  • Screw misplacement in percutaneous posterior pelvic iliosacral screwing with and without navigation: A prospective clinical study of 174 screws in 127 patients
  • Mehdi Boudissa, Delphine Carmagnac, Gaël Kerschbaumer, Sébastien Ruatti, Jérôme Tonetti
| Article suivant Article suivant
  • Posterior hinge fixation for the treatment of unstable traumatic sacroiliac joint injuries
  • Rémi Gauthé, Émeric Lefèvre, Franck Dujardin, Emmanuel Foulongne, Étienne Hoffmann, Matthieu Lalevée, Mourad Ould-Slimane

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.