S'abonner

Survival and complications of total hip arthroplasty using third-generation dual-mobility cups with non-cross-linked polyethylene liners in patients younger than 55 years - 13/04/22

Doi : 10.1016/j.otsr.2022.103208 
Chloé Viricel a, , Bertrand Boyer a, b, Rémi Philippot a, c, Frédéric Farizon a, b, Thomas Neri a, c
a Service de chirurgie orthopédique et traumatologique, centre hospitalo-universitaire de Saint-Étienne, Hôpital Nord, 42055 Saint-Étienne, France 
b INSERM U1059 (SAINBIOSE), Université Jean-Monnet, Saint-Étienne, France 
c EA 7424, Inter-university Laboratory of Human Movement Science, Université de Lyon – Université Jean-Monnet, Saint-Étienne, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

In younger patients, total hip prostheses are subjected to wide motion ranges and wear-inducing forces. Dual-mobility cups (DMCs) are effective in decreasing the risk of dislocation. However, wear and osteolysis have been reported with first-generation DMCs. These complications have not been assessed in younger patients managed with third-generation DMCs associated with a lower risk of intra-prosthetic dislocation (IPD). We therefore designed a retrospective study of patients younger than 55years at THA with third-generation DMCs. Our objectives were to evaluate (1) the complication rate, and (2) the survival rate.

Hypothesis

The rate of complications of THA with third-generation DMCs in patients younger than 55years of age is comparable to that in the general population of THA patients.

Material and methods

This retrospective study included 79 consecutive patients (91 hips) who had total hip arthroplasty (THA) between 2007 and 2012. We included all patients younger than 55years who underwent primary THA with a third-generation DMC and a liner made of non-cross-linked polyethylene. The patients were evaluated clinically and radiologically.

Results

Mean follow-up was 9.8years (range: 2–13years). At last follow-up, no patient had experienced prosthetic dislocation or IPD. Aseptic and septic cup loosening each occurred in 1 patient. In all, 7 (7.7%) patients required revision surgery with exchange of at least one component (cup loosening, n=2; neck fracture with a short stem fixed to the neck, n=1; peri-prosthetic femoral fracture, n=1; infection, n=1; and femoral-stem loosening, n=2). Peri-acetabular osteolysis developed in 2 (2.2%) hips. Cup survival to aseptic loosening was 98.9% (95% confidence interval, 97%–100%) and survival to revision for any reason except infection was 95.6% (95% confidence interval, 82%–100%).

Discussion

In patients younger than 55years, third-generation DMCs were associated with absence of prosthetic dislocation, absence of IPD, and a low revision rate for cup loosening, in the medium term. These implants therefore constitute a viable treatment option in younger patients requiring THA.

Level of evidence

IV, retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Dual-mobility cup, Age less than 55years, Total hip arthroplasty, Survival


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 2

Article 103208- avril 2022 Retour au numéro
Article précédent Article précédent
  • The significant relationship among the factors of pelvic incidence, standing lumbar lordosis, and lumbar flexibility in Japanese patients with hip osteoarthritis: A descriptive radiographic study
  • Takaomi Kobayashi, Tadatsugu Morimoto, Tomohito Yoshihara, Motoki Sonohata, Charles Rivière, Masaaki Mawatari
| Article suivant Article suivant
  • Cementless hydroxyapatite-coated stem with dual mobility and posterior approach in over-80 year-old patients with osteoarthritis: Rates of dislocation and periprosthetic fracture at a mean 8 years’ follow-up
  • Vincent Belgaïd, Anthony Viste, Michel-Henri Fessy

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.