S'abonner

Twelve lateral flow immunoassays (LFAs) to detect SARS-CoV-2 antibodies - 02/03/22

Doi : 10.1016/j.jinf.2021.12.007 
Sophie I. Owen a, 1, Christopher T. Williams a, 1, Gala Garrod a, Alice J. Fraser a, Stefanie Menzies a, Lisa Baldwin a, Lottie Brown a, Rachel L. Byrne a, Andrea M. Collins b, d, Ana I. Cubas-Atienzar a, Margaretha de Vos c, Thomas Edwards a, Camille Escadafal c, Daniela M. Ferreira d, Tom Fletcher b, Angela Hyder-Wright b, d, Grant A. Kay a, Konstantina Kontogianni a, Jenifer Mason e, Elena Mitsi d, Tim Planche f, g, Jilian A. Sacks c, Joseph Taylor e, Stacy Todd b, Caroline Tully c, Luis E. Cuevas a, Emily R. Adams a,
a Centre for Drugs and Diagnostics Research, Liverpool School of Tropical Medicine (LSTM), Liverpool, United Kingdom 
b Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom 
c FIND, Geneva, Switzerland 
d Department of Clinical Sciences, Liverpool School of Tropical Medicine (LSTM), Liverpool, United Kingdom 
e Liverpool Clinical Laboratories, Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom 
f Institute for Infection and Immunity, St George's University of London, London, United Kingdom 
g St George's University Hospitals NHS Foundation Trust, London, United Kingdom 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

There are an abundance of commercially available lateral flow assays (LFAs) that detect antibodies to SARS-CoV-2. Whilst these are usually evaluated by the manufacturer, externally performed diagnostic accuracy studies to assess performance are essential. Herein we present an evaluation of 12 LFAs.

Methods

Sera from 100 SARS-CoV-2 reverse-transcriptase polymerase chain reaction (RT-PCR) positive participants were recruited through the FASTER study. A total of 105 pre-pandemic sera from participants with other infections were included as negative samples.

Results

At presentation sensitivity against RT-PCR ranged from 37.4 to 79% for IgM/IgG, 30.3–74% for IgG, and 21.2–67% for IgM. Sensitivity for IgM/IgG improved ≥ 21 days post symptom onset for 10/12 tests. Specificity ranged from 74.3 to 99.1% for IgM/IgG, 82.9–100% for IgG, and 75.2–98% for IgM. Compared to the EuroImmun IgG enzyme-linked immunosorbent assay (ELISA), sensitivity and specificity ranged from 44.6 to 95.4% and 85.4–100%, respectively.

Conclusion

There are many LFAs available with varied sensitivity and specificity. Understanding the diagnostic accuracy of these tests will be vital as we come to rely more on the antibody status of a person moving forward, and as such manufacturer-independent evaluations are crucial.

Le texte complet de cet article est disponible en PDF.

Keywords : SARS-CoV-2, Lateral flow immunoassays, COVID-19, IgM, IgG


Plan


© 2021  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 84 - N° 3

P. 355-360 - mars 2022 Retour au numéro
Article précédent Article précédent
  • Using artificial intelligence-based models to predict the risk of mucormycosis among COVID-19 survivors: An experience from a public hospital in India
  • Shabbir Syed-Abdul, A. Shoban Babu, Raja Shekhar Bellamkonda, Ramaiah Itumalla, GVRK Acharyulu, Surya Krishnamurthy, Y. Venkat Santosh Ramana, Naresh Mogilicharla, Shwetambara Malwade, Yu-Chuan Li
| Article suivant Article suivant
  • Transmission of SARS-CoV-2 by children and young people in households and schools: A meta-analysis of population-based and contact-tracing studies
  • Russell Viner, Claire Waddington, Oliver Mytton, Robert Booy, Joana Cruz, Joseph Ward, Shamez Ladhani, Jasmina Panovska-Griffiths, Chris Bonell, G.J. Melendez-Torres

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.