S'abonner

Using a human factors-centric approach to development and testing of a face shield designed for health care workers: A COVID-19 case study for process and outcomes - 24/02/22

Doi : 10.1016/j.ajic.2021.10.033 
Camden E. Kurtz, MS a, Yuhao Peng, MS b, Matthew Jesso, MA b, Harsh Sanghavi, MS b, Damon R. Kuehl, MD a, c, Sarah H. Parker, PhD, MA a, d, e,
a Virginia Tech Carilion School of Medicine, Roanoke, VA 
b Human Factors, Carilion Clinic, Roanoke, VA 
c Department of Emergency Medicine, Carilion Clinic, Roanoke, VA 
d Center for Simulation, Research, and Patient Safety, Carilion Clinic, Roanoke, VA 
e Fralin Biomedical Research Institute, Virginia Tech, Roanoke, VA 

Address correspondence to Sarah H. Parker, PhD, MA, 2 Riverside Circle, Roanoke, VA 24016.2 Riverside CircleRoanokeVA24016

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

This study developed criteria for a faceshield for use in healthcare.
Using rapid-cycle prototyping, we developed and tested faceshield designs.
A human factors approach and frontline user testing is feasible and valuable.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

Face shields are a critical piece of personal protective equipment and their comfort impacts compliant use and thus protectiveness. Optimal design criteria for face shield use in healthcare environments are limited. We attempt to identify factors affecting face shield usability and to test and optimize a face shield for comfort and function in health care settings.

Methods

A broad range of workers in a large health care system were surveyed regarding face shield features and usability. Quantitative and qualitative analysis informed the development of iterative prototypes which were tested against existing shields. Iterative testing and redesign utilized expert insight and feedback from participant focus groups to inform subsequent prototype designs.

Results

From 1,648 responses, 6 key elements were identified: ability to adjust tension, shifting load bearing from the temples, anti-fogging, ventilation, freedom of movement, and durability. Iterative prototypes received consistently excellent feedback based on use in the clinical environment, demonstrating incremental improvement.

Conclusion

We defined elements of face shield design necessary for usability in health care and produced a highly functional face shield that satisfies frontline provider criteria and Emergency Use Authorization standards set by the Food and Drug Administration. Integrating human factors principles into rapid-cycle prototyping for personal protective equipment is feasible and valuable.

Le texte complet de cet article est disponible en PDF.

Key Words : Personal protective equipment (PPE), Iterative design, Occupational safety, Human centered design


Plan


 Conflicts of interest: The authors do not have any conflicts of interest to disclose.


© 2021  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 50 - N° 3

P. 306-311 - mars 2022 Retour au numéro
Article précédent Article précédent
  • Personal protective equipment in Covid-19: Evidence-based quality and analysis of YouTube videos after one year of pandemic
  • Gerardo Gerundo, Claudia Collà Ruvolo, Brunella Puzone, Gianluigi Califano, Roberto La Rocca, Valentina Parisi, Marco Capece, Giuseppe Celentano, Massimiliano Creta, Giuseppe Rengo, Dario Leosco, Pasquale Abete, Nicola Longo, Vincenzo Mirone, Nicola Ferrara
| Article suivant Article suivant
  • Fear for CoViD-19 and reluctance to work among health care workers during the epidemic, a prospective monocentric cohort study
  • Marco Moretti, Deborah De Geyter, Ellen Van Cutsem, Sven Van Laere, Denis Pierard, Sabine Danielle Allard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.