S'abonner

Linear and angular transfer accuracy of labial brackets using three dimensional-printed indirect bonding trays: A systematic review and meta-analysis - 18/02/22

Doi : 10.1016/j.ortho.2022.100612 
Wesam Mhd Mounir Bakdach , Rania Hadad
 Department of Orthodontics, University of Damascus Dental School, Damascus, Syria 

Wesam M.M. Bakdach, Department of Orthodontics, University of Damascus Dental School, Damascus, Syria.Department of Orthodontics, University of Damascus Dental SchoolDamascusSyria

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 11
Iconographies 3
Vidéos 0
Autres 0

Summary

Objectives

To assess the transfer accuracy of three dimensional-printed trays (3D-printed trays) and to compare the accuracy of this approach with the other methods used for the same purpose.

Materials and Methods

An electronic search was performed in PubMed, Scopus, Web of science, Google Scholar and ProQuest (dissertation and theses). Studies were eligible for inclusion if they involved the assessment of transfer errors measured by the superimposition of the original set-up of brackets and the final positions after transfer. Risk of bias was assessed using Cochrane's tools.

Results

Seven studies were included. The pooled estimate of the transfer error in the linear dimensions showed an error of 0.095mm in the mesiodistal direction (95%CI: 0.035, 0.155), 0.114mm in the buccolingual direction (95%CI: 0.067, 0.160) and 0.111mm in the vertical direction (95%CI: -0.033, 0.255). Concerning the angular dimensions, the pooled estimate showed a tipping error of 1.3420 (95%CI: 0.444, 2.240), rotational error of 0.9980 (95%CI: 0.323, 1.672), and torque error of 1.9130 (95%CI: 0.922, 2.903). Thus, the maximum transfer error was in the bucco-lingual and torque directions. 3D-printed trays had better control in mesiodistal and vertical directions than vacuum-formed trays. Polyvinyl siloxane trays were more accurate in the vertical direction than 3D-printed trays. The scarcity of randomized clinical trials is the main risk of bias of the included studies.

Conclusions

According to the available evidence, 3D-printed trays have an acceptable transfer accuracy, based on the American Board of Orthodontics Objective Grading System (ABO OGS), with maximum linear transfer error in the buccolingual direction and maximum angulation error in the torque. Conducting randomized clinical trials on this topic is highly recommended.

Le texte complet de cet article est disponible en PDF.

Keywords : Transfer accuracy, Indirect bonding, Bracket positioning, Three dimensional-printing, CAD-CAM


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 1

Article 100612- mars 2022 Retour au numéro
Article précédent Article précédent
  • The adjunctive effect of autologous platelet concentrates on orthodontic tooth movement: A systematic review and meta-analysis of current randomized controlled trials
  • Nima Farshidfar, Mohammad Amin Amiri, Parsa Firoozi, Shahram Hamedani, Shabnam Ajami, Lobat Tayebi
| Article suivant Article suivant
  • Changes in surface morphology, chemical and mechanical properties of clear aligners during intraoral usage: A systematic review and meta-analysis
  • Wesam Mhd Mounir Bakdach, Majed Haiba, Rania Hadad

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.