Modified long-axis in-plane ultrasound-guided radial artery cannulation in adult patients: A randomized controlled trial - 08/02/22
pages | 7 |
Iconographies | 5 |
Vidéos | 0 |
Autres | 0 |
Highlights |
• | A modified ultrasound approach increased the success rate of arterial cannulation. |
• | The modified approach showed shorter cannulation time and a lower rate of haematoma. |
• | The artery axis is kept in the ultrasound plane to obtain the maximum artery diameter. |
• | Two signal lines on the probe increase the geometrical accuracy of puncturing. |
Abstract |
Introduction |
For adults with small radial arteries, ultrasound-guided radial artery cannulation remains challenging and the relevant data is currently lacking. The study aimed to test the hypothesis that modified long-axis in-plane ultrasound guidance (M-LAIP) would improve success rates of radial artery cannulation in this population.
Patients and methods |
This was a prospective, randomised, and controlled clinical study that enrolled 201 adult patients with diameters of the radial artery less than 2.2 mm. Patients were randomised to M-LAIP, short-axis out-of-plane (SAOP), or conventional palpation (C-P) group according to different approaches of radial artery cannulation (M-LAIP, SAOP, and C-P). Outcome measurements included the success rate, cannulation time, and cannulation-related adverse events.
Results |
The cannulation success rate was significantly higher in the M-LAIP group than in the SAOP or C-P groups (first success rate: 80.3% vs. 53.8% or 33.8%; P < 0.001; total success rate: 93.9% vs. 78.5% or 50.8%; P < 0.001). Total cannulation time in the M-LAIP group was shorter than that in the SAOP group (P = 0.002) or the C-P group (P < 0.001). The rates of posterior wall puncture and haematoma in the M-LAIP group were lower than that in the SAOP group or C-P group (P < 0.008).
Conclusion |
The use of the M-LAIP approach significantly improved the success rate of radial artery cannulation, shortened procedure time, and lowered the rates of posterior wall puncture and haematoma in adults with radial artery diameters less than 2.2 mm, compared with that achieved by the SAOP or C-P approach.
Le texte complet de cet article est disponible en PDF.Abbreviations : SAX, LAX, M-LAIP, SAOP, C-P, IQR, CI, OR, Rho
Keywords : Ultrasound, Surgery, Intensive care, Anaesthesia
Plan
Vol 41 - N° 1
Article 100989- février 2022 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.
Déjà abonné à cette revue ?