S'abonner

Outcomes and survival of a modern dual mobility cup and uncemented collared stem in displaced femoral neck fractures at a minimum 5-year follow-up - 03/02/22

Doi : 10.1016/j.otsr.2021.103164 
Maxence Bordes a, Anthony Viste a, b, , Mathieu Fauvernier c, d, Marcelle Mercier a, Philippe Chaudier a, Mathieu Severyns e, Michel-Henri Fessy a, b
a Service de chirurgie orthopédique et traumatologique, Hospices Civils de Lyon, Hôpital Lyon Sud, Service de Chirurgie Orthopédique et Traumatologique, 165, chemin du Grand-Revoyet, 69495 Pierre-Benite cedex, France 
b LBMC UMRT_9406, université de Lyon, Université de Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, LBMC UMRT_9406, Lyon, France 
c CNRS, UMR 5558, laboratoire de biométrie et biologie évolutive, équipe biostatistique-santé, université de Lyon, université Lyon 1, Villeurbanne, France 
d Pôle santé publique, service de biostatistique – bioinformatique, hospices civils de Lyon, Lyon, France 
e Département de chirurgie orthopédique, hôpital Pierre Zobda-Quitman, CHU de Martinique, 97261 Fort-de-France, France 

Corresponding author. Service de chirurgie orthopédique et traumatologique, hospices civils de Lyon, hôpital Lyon Sud, 165, chemin du Grand-Revoyet, 69495 Pierre-Benite cedex, France.Service de chirurgie orthopédique et traumatologique, hospices civils de Lyon, hôpital Lyon Sud165, chemin du Grand-RevoyetPierre-Benite cedex69495France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

The choice of implant type for total hip replacement in the treatment of femoral neck fractures remains debated. Some authors advocate for the systematic use of cemented stems, while others do not use dual mobility first-line. We therefore conducted a retrospective study using a dual mobility cup (DMC) and an uncemented collared stem (UCS) in order to: (1) confirm the low dislocation rate in this indication, (2) assess other surgical complications, in particular periprosthetic fractures, (3) ensure that these benefits are maintained over time, at a minimum follow-up of 5 years and, (4) assess the rate of revision of the implants.

Hypothesis

Our hypothesis was that the dual mobility dislocation rate for the treatment of femoral neck fractures was lower than for bipolar hemiarthroplasties or single mobility hip prostheses.

Patients and methods

A retrospective study of 244 femoral neck fractures (242 patients) treated with DMC and UCS was conducted, between 2013 and 2014. The mean age was 83±10 years (60–104). The occurrence of dislocation, periprosthetic fracture, infection of the surgical site, loosening, reoperation and revision were investigated. The HOOS Joint Replacement (JR) score was collected. The cumulative incidence with mortality was used as a competing risk.

Results

The mean follow-up was 6 years±0.5 (5–7). At the last follow-up, 108 patients (50%) had died. Twenty-three patients (9.5%) were lost to follow-up. One case of symptomatic aseptic loosening of DMC was observed. The cumulative incidence of dislocations and periprosthetic fractures at 5 years were 2% (95% CI: 0.9–5.4) and 3% (95% CI: 1.2–6), respectively. The 5-year cumulative incidence of surgical site infections was 3.5% (95% CI: 1.8–7). The cumulative incidence of reoperations at 5 years was 7% (95% CI: 4.5–11). The causes of reoperation were periprosthetic fracture (n=6), infection (n=8), postoperative hematoma (n=2) and cup malposition (n=2). The cumulative incidence of a revision at 5 years was 2.7% (95% CI: 1.2–6). The cumulative incidence of a surgical complication from any cause at 5 years was 9% (95% CI: 6.7–14.8). The mean HOOS JR score was 79±5 (52–92).

Discussion

The cumulative incidence of dislocation at 5 years is low and other surgical complications (including periprosthetic fractures) do not increase during this period for DMC associated with UCS, in femoral neck fractures. The use of this type of implant is reliable in the treatment of femoral neck fractures.

Level of evidence

IV; retrospective study without control group.

Le texte complet de cet article est disponible en PDF.

Keywords : Dual mobility, Uncemented stem, Displaced femoral neck fracture, Total hip arthroplasty, Hip Dislocation, Periprosthetic fracture


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 1

Article 103164- février 2022 Retour au numéro
Article précédent Article précédent
  • Fracture fixation versus hemiarthroplasty for unstable intertrochanteric fractures in elderly patients: A systematic review and network meta-analysis of randomized controlled trials
  • Natthapong Hongku, Patarawan Woratanarat, Lertkong Nitiwarangkul, Sasivimol Rattanasiri, Ammarin Thakkinstian
| Article suivant Article suivant
  • Comparative study of total hip arthroplasties with dual mobility cups versus hemiarthroplasties in management of femoral neck fractures: Survival and dislocation rate at 5 years of follow-up?
  • Juliette Bertault-Le Gourrierec, Etienne Cavaignac, Emilie Berard, Federico Moretti, Vincent Marot, Philippe Chiron, Nicolas Reina

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.