S'abonner

Determination of Brain Death in Patients Undergoing Short-Term Mechanical Circulatory Support Devices - 10/01/22

Doi : 10.1016/j.hlc.2021.05.100 
Ibrahim Migdady, MD a, b, , Aaron Shoskes, DO b, Moein Amin, MD b, Sung-Min Cho, DO, MHS c, Alexander Rae-Grant, MD b, Pravin George, DO d
a Division of Neurocritical Care, Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA 
b Department of Neurology, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA 
c Division of Neuroscience Critical Care, Departments of Neurology, Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA 
d Department of Neurointensive Care, Cerebrovascular Center, Cleveland Clinic, OH, USA 

Corresponding author at: Division of Neurocritical Care, Department of Neurology, Massachusetts General Hospital, 55 Fruit Street, Lunder 650, Boston, MA 02114, USADivision of Neurocritical CareDepartment of NeurologyMassachusetts General Hospital55 Fruit Street, Lunder 650BostonMA02114USA

Abstract

Objective

To describe apnoea test (AT) and ancillary study performance for brain death (BD) determination among patients undergoing short-term mechanical circulatory support (MCS) devices, including extracorporeal membrane oxygenation (ECMO) and intra-aortic balloon pump (IABP).

Methods

We retrospectively analysed data regarding use of AT and ancillary study in consecutive adult patients who were diagnosed with BD while on MCS devices (including ECMO and IABP) over a 10-year period.

Results

Out of 140 patients, eight were on MCS devices at the time of BD (four ECMO, two ECMO and IABP, two IABP). The most common aetiology of BD was hypoxic ischaemic brain injury (6/8, 75%). In four patients (50%), the AT was not attempted because of haemodynamic instability and ECMO; in the remaining four (50%), both AT and ancillary studies were used. In three patients on ECMO, AT was performed by reducing the ECMO sweep flow rate to a range 0.5–2.7 L/min in order to achieve hypercarbia. One patient underwent AT while on IABP which was complicated by hypotension. All patients underwent ancillary tests, most commonly transcranial Doppler ultrasonography (TCD) (7/8, 88%); among those, cerebral circulatory arrest was confirmed in six of seven patients (86%), all of whom had left ventricular ejection fracture (LVEF) ≥20% and/or were supported with IABP.

Conclusions

There are multiple uncertainties regarding BD diagnosis while on MCS, prompting the need for ancillary studies in most patients. Our study shows that TCD can be used to support BD diagnosis in patients on ECMO who have sufficient cardiac contractility and/or IABP to produce pulsatile flow. TCD use in ECMO patients low LVEF needs further study.

Le texte complet de cet article est disponible en PDF.

Keywords : Brain death, Mechanical circulatory support, ECMO, IABP, Apnoea test


Plan


 Institution where the work was conducted: Cleveland Clinic Foundation, Cleveland, OH.


© 2021  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 31 - N° 2

P. 239-245 - février 2022 Retour au numéro
Article précédent Article précédent
  • Clinical Features and Outcomes of Pulmonary Artery Sarcoma
  • Jifeng Li, Lin Liu, Ling-Xie Song, Yu-Hui Zhang, Yan Liu, Song Gu, Jian-Feng Wang, Qiang Huang, Zhan-Hong Ma, Xiao-Juan Guo, Min-Fu Yang, Wei Jiang, Feng Li, Yuan-Hua Yang
| Article suivant Article suivant
  • Outcomes of Cardiac Arrest and Cardiopulmonary Resuscitation in Patients With Left Ventricular Assist Device; an Insight From a National Inpatient Sample
  • Kirolos Barssoum, Harsh Patel, Devesh Rai, Ashish Kumar, Mohab Hassib, Hasan F. Othman, Samarthkumar Thakkar, Ahmed El Karyoni, Osarenren Idemudia, Fadi Ibrahim, Tala Salem, Mariam Shariff, Ahmad Jabri, Ayman ElBadawi, Soidjon Khodjaev, Dhrubajyoti Bandyopadhyay, Wilbert S. Aronow, Vishal Parikh, Mohan Rao, Park Soon

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.