S'abonner

The use of a pediatric appendicitis pathway in a large integrated health system reduced computed tomography imaging in the ED - 30/11/21

Doi : 10.1016/j.ajem.2021.07.064 
Emine Tunc, MD a, Erika Fraundorf, MD b, Sarah Worley, MS c, Michael Aquino, MD MHS d, David Magnuson, MD e, Brooke S. Lampl, DO d, Stephanie Jennings, MD f, Baruch S. Fertel, MD, MPA g,
a Department of Pediatrics, University of Washington, Seattle, WA, United States of America 
b Division of Pediatric Emergency Medicine, Emergency Services Institute, Cleveland Clinic Health System and Lerner College of Medicine in Cleveland Ohio, United States of America 
c Department of Quantitative Health Sciences, Cleveland Clinic Health System and Lerner College of Medicine in Cleveland Ohio, United States of America 
d Division of Pediatric Radiology, Imaging Institute, Cleveland Clinic Health System and Lerner College of Medicine in Cleveland Ohio, United States of America 
e Division of Pediatric Surgery, Digestive Disease Institute, Cleveland Clinic Health System and Lerner College of Medicine in Cleveland Ohio, United States of America 
f Division of Pediatric Hospital Medicine, Pediatric Institute, Cleveland Clinic Health System and Lerner College of Medicine in Cleveland Ohio, United States of America 
g Emergency Services Institute and Enterprise Quality and Safety, Cleveland Clinic Health System and Lerner College of Medicine in Cleveland Ohio, United States of America 

Corresponding author at: Emergency Services Institute, E19, Cleveland Clinic Health System, 9500 Euclid Avenue, Cleveland, Ohio 44195, United States of America.Emergency Services InstituteE19, Cleveland Clinic Health System9500 Euclid AvenueClevelandOhio44195United States of America

Abstract

Background

Appendicitis is the most common cause of an acute surgical abdomen in children. Diagnosis is often challenging as few pediatric patients present with classic symptoms. Clinicians are thus dependent on imaging to reach an accurate diagnosis. Although computerized tomography (CT) has high sensitivity and specificity, it has the disadvantage of imparting ionizing radiation. Ultrasound (US) is readily available and has comparable accuracy to CT when performed by experienced sonographers. We sought to examine the impact of a system-wide process improvement plan on CT use and other metrics in pediatric patients who presented to the Emergency Department (ED) with suspected appendicitis.

Methods

This is a retrospective study of the impact of a Pediatric Appendicitis Pathway (PAP) within a large integrated hospital system with 12 EDs including 3 designated hub EDs. Patients were placed in an initial risk category utilizing the Pediatric Appendicitis Score (PAS), and received US of the appendix at a hub ED if indicated by the PAS. Patients presenting to community EDs who required US appendix were transferred to hub EDs for imaging. Patients presenting in the 6-month pre-implementation period were compared to patients presenting in a 14-month post-implementation period on CT and US utilization, negative and missed appendectomy rates, and ED length of stay (LOS).

Results

1874 patients (401 pre-PAP and 1473 post-PAP) were included in the study. At the hub EDs the rate of CT imaging for suspected appendicitis was reduced from 31% to 17% with a resultant increase in US utilization from 83% (333/401) to 90% (1331/1473) (p < 0.001). At community general EDs (404 pre-PAP and 449 post-PAP), the rate of CT was decreased from 45% (181/404) to 32%(144/449) (p < 0.001)) There was no significant change in the negative appendectomy rate pre-PAP (1/59 = 1.7%) and post-PAP (4/168 = 2.4%) (p = 0.99) at the hub EDs. There were no missed appendicitis cases after PAP implementation compared to 1 case in the pre-PAP period. Overall LOS was similar pre and post-PAP, however LOS was longer in patients that required transfer from community general EDs to hub EDs (median 264 vs 342 min, p < 0.001).

Conclusions

A PAP that stratified patients into risk groups using the PAS and encouraged the use of US as a first line imaging modality, reduced the number of CT performed in a large integrated health system without significant changes to clinical outcomes. Furthermore, transferring select patients for an US as opposed to obtaining an initial CT in community general EDs was feasible and reduced CT use in the pediatric population.

Le texte complet de cet article est disponible en PDF.

Keywords : Emergency medicine, Appendicitis, QA, Care path, Systems of care, CT, Ultrasound, Pediatric surgery


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 50

P. 211-217 - décembre 2021 Retour au numéro
Article précédent Article précédent
  • Passive antipyretic therapy is not as effective as invasive hypothermia for maintaining normothermia after cardiac arrest
  • Talal S. Alnabelsi, Sarah P. Faulkner, Matthew Cook, Kalen Freeman, Julie Shelton, Marc Paranzino, Sethabhisha Nerusu, Susan S. Smyth, Vedant A. Gupta
| Article suivant Article suivant
  • A nomogram predicting severe COVID-19 based on a large study cohort from China
  • Songqiao Liu, Huanyuan Luo, Zhengqing Lei, Hao Xu, Tong Hao, Chuang Chen, Yuancheng Wang, Jianfeng Xie, Ling Liu, Shenghong Ju, Haibo Qiu, Duolao Wang, Yi Yang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.