S'abonner

Sinus augmentation - autograft vs. fresh frozen allograft: Bone density dynamics and implant stability - 09/11/21

Doi : 10.1016/j.jormas.2020.08.012 
Liat Chaushu a , Erick Ricardo Silva b , Vitor Ferreira Balan c , Gavriel Chaushu d, , Samuel Porfirio Xavier e
a Attending, Department of Periodontology and Implant Dentistry, School of Dentistry, Tel Aviv University, Israel 
b Attending, Department of Oral and Maxillofacial Surgery and Periodontology School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil 
c MSc Student in Oral and Maxillofacial Surgery - Dental School of University of Sao Paulo - Ribeirão Preto, University of São Paulo, São Paulo, Brazil 
d Department of Oral & Maxillofacial Surgery, School of Dental Medicine, Tel Aviv University, Tel-Aviv, Department of Oral & Maxillofacial Surgery, Rabin Medical Center, Campus Beilinson, Petah Tiqwa, Israel 
e Department of Oral and Maxillofacial Surgery and Periodontology. School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 3
Vidéos 0
Autres 0

Abstract

Objectives

Compare bone density changes and initial implant stability following sinus augmentation with autogenous bone (AB) vs. fresh frozen bone (FFB).

Materials and methods

Randomized, prospective, split mouth study. Sinus augmentation executed using either AB or FFB. Dental implants were inserted after 6 months of healing. Implant dimensions and insertion torques were recorded. Prostheses were delivered 6 months thereafter. All patients had computerized tomography (CT) scans 1 week (T1) and 6 months (T2) after initial bone grafting. Third CT (T3) was taken 12 months after prosthesis delivery. Data from CT scans was used to analyze bone density at each period.

Results

A total of 15 patients (8 males, 7 females) following bilateral sinus augmentation procedures, were included. Mean age was 54 ± 5 years (range 48–60 years). All patients had 3 CT examinations. The initial augmented AB density was higher than the initial FFB density. Nevertheless, density differences between the two groups were not statistically significant at any time frame. At T2 density of both grafts showed a statistically significant increase. A significant increase from T2 to T3 was noted only for the FFB group. Implant insertion torque was significantly higher in the FFB group. Insertion torque ≥32 N/cm was achieved in significantly more patients in the FFB group.

Conclusion

The use of FFB for sinus augmentation is a reliable option of graft material. The newly formed bone quality performance, evaluated by CBCT density, is as good as AB, allowing predictable initial implant stability and osseointegration. Unnecessary morbidity associated with AB harvesting is thus avoided.

Le texte complet de cet article est disponible en PDF.

Keywords : Sinus augmentation, Allograft, Autogenous bone graft, Density, Insertion torque, Implant stability


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 122 - N° 5

P. 467-471 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • Editorial board
| Article suivant Article suivant
  • Assessing the incidence of nerve injuries according to different mandibular osteotomies including Wing osteotomies
  • G. Cordier, N. Sigaux, J. Giai, B. Ibrahim, P. Cresseaux

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.