S'abonner

Rigid Ring Versus Flexible Band for Tricuspid Valve Repair in Patients Scheduled for Mitral Valve Surgery: A Prospective Randomised Study - 03/11/21

Doi : 10.1016/j.hlc.2021.08.009 
Alexander V. Bogachev-Prokophiev, MD, Michail A. Ovcharov, MD , Andrey V. Sapegin, MD, Sergey O. Lavinykov, MD, Dmitriy A. Astapov, MD, Sergey M. Ivanzov, MD, Ravil M. Sharifulin, MD, Alexander V. Afanasyev, MD, Igor I. Demin, MD, Sergey I. Zeleznev, MD
 Heart Valves Surgery Department, E. Meshalkin National Medical Research Center, Novosibirsk, Russian Federation 

Corresponding author at: Heart Valves Surgery Department, E. Meshalkin National Medical Research Center, 15 Rechkunovskaya St., 630055 Novosibirsk, Russian FederationHeart Valves Surgery DepartmentE. Meshalkin National Medical Research Center15 Rechkunovskaya St.Novosibirsk630055Russian Federation

Abstract

Background

Tricuspid valve repair for functional regurgitation is effectively performed with different annuloplasty devices. However, it remains unclear whether there are advantages associated with rigid rings compared to flexible bands. This prospective randomised study aimed to compare results of using a flexible band ring versus a rigid ring for functional tricuspid regurgitation in patients undergoing mitral valve surgery.

Methods

A single-centre randomised study was designed to allocate patients with functional tricuspid regurgitation undergoing mitral valve surgery to be treated with a flexible band or rigid ring. These patients were analysed by echocardiographic follow-up. The primary outcome was freedom from recurrent tricuspid regurgitation at 12-months follow-up. Secondary outcomes were 30-day mortality, survival, freedom from tricuspid valve reoperation, right ventricular reverse remodelling, and rate of major adverse events.

Results

A total of 308 patients were allocated to receive concomitant tricuspid valve annuloplasty with the flexible band or rigid ring. There was no between-group difference in freedom from recurrent tricuspid regurgitation: 97.3% in Rigid group (95% CI, 93.0–98.8) and 96.2% in the Flexible group (95% CI, 92.0–98.5) at 12-months follow-up (log-rank, p=0.261). Early mortality, survival, freedom from tricuspid valve reoperation, and global right ventricle systolic function were also comparable in both groups of patients. However, the flexible band had advantage in restoring regional right ventricle function (Doppler-derived systolic velocities of the annulus [S], tricuspid annular plane systolic excursion) at 12-months follow-up.

Conclusion

Both the rigid ring and flexible band offered acceptable outcomes for functional tricuspid regurgitation correction without significant differences, as assessed at 12-months follow-up.

Le texte complet de cet article est disponible en PDF.

Keywords : Tricuspid regurgitation, Tricuspid valve repair, Ring annuloplasty, Rigid ring, Flexible band, Mitral valve surgery


Plan


© 2021  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 12

P. 1949-1957 - décembre 2021 Retour au numéro
Article précédent Article précédent
  • Preoperative CHA2DS2-VASc Score is Associated With Postoperative Survival Following Surgical Ablation Concomitantly With Other Cardiac Surgery
  • Daniel Julius Lauritzen, Henrik Jensen Vodstrup, Thomas Decker Christensen, Mine Onat Hald, Rasmus Christensen, Johan Heiberg
| Article suivant Article suivant
  • Takotsubo Cardiomyopathy After mRNA COVID-19 Vaccination
  • Martina Boscolo Berto, Giancarlo Spano, Benedikt Wagner, Benedikt Bernhard, Jonas Häner, Adrian T. Huber, Christoph Gräni

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.