S'abonner

Automated pupillometry helps monitor the efficacy of cardiopulmonary resuscitation and predict return of spontaneous circulation - 29/10/21

Doi : 10.1016/j.ajem.2021.06.058 
Lin Shi, MD, PhD a, b , Jiefeng Xu, MD, PhD a, b , Jiangang Wang, MD c, Minhai Zhang, MD, PhD a, b , Fei Liu, MD, PhD a, b , Zafar Ullah Khan, MD, PhD a, b, Shaoyun Liu, MD, PhD a, b , Wen Zhou, MD a, b , Anyu Qian, MD, PhD a, b , Jungen Zhang, MD c, Mao Zhang, MD, PhD a, b,
a Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China 
b Institute of Emergency Medicine, Zhejiang University, Hangzhou, Zhejiang, China 
c Hangzhou Emergency Medical Center of Zhejiang Province, Hangzhou, Zhejiang, China 

Corresponding author at: Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, No. 88 Jiefang road, 310009 Hangzhou, China.Department of Emergency MedicineSecond Affiliated HospitalZhejiang University School of Medicine & Institute of Emergency MedicineZhejiang UniversityNo. 88 Jiefang roadHangzhou310009China

Abstract

Background

We investigated the effectiveness of automated pupillometry on monitoring cardiopulmonary resuscitation (CPR) and predicting return of spontaneous circulation (ROSC) in a swine model of cardiac arrest (CA).

Methods

Sixteen male domestic pigs were included. Traditional indices including coronary perfusion pressure (CPP), end-tidal carbon dioxide (ETCO2), regional cerebral tissue oxygen saturation (rSO2) and carotid blood flow (CBF) were continuously monitored throughout the experiment. In addition, the pupillary parameters including the initial pupil size before constriction (Init, maximum diameter), the end pupil size at peak constriction (End, minimum diameter), and percentage of change (%PLR) were measured by an automated quantitative pupillometer at baseline, at 1, 4, 7 min during CA, and at 1, 4, 7 min during CPR.

Results

ROSC was achieved in 11/16 animals. The levels of CPP, ETCO2, rSO2 and CBF were significantly greater during CPR in resuscitated animals than those non-resuscitated ones. Init and End were decreased and %PLR was increased during CPR in resuscitated animals when compared with those non-resuscitated ones. There were moderate to good significant correlations between traditional indices and Init, End, and %PLR (|r| = 0.46–0.78, all P < 0.001). Furthermore, comparable performance was also achieved by automated pupillometry (AUCs of Init, End and %PLR were 0.821, 0.873 and 0.821, respectively, all P < 0.05) compared with the traditional indices (AUCs = 0.809–0.946).

Conclusion

The automated pupillometry may serve as an effective surrogate method to monitor cardiopulmonary resuscitation efficacy and predict ROSC in a swine model of cardiac arrest.

Le texte complet de cet article est disponible en PDF.

Keywords : Pupillometry, Pupil light reflex, Return of spontaneous circulation, Cardiac arrest, Cardiopulmonary resuscitation, Resuscitation quality

Abbreviations : AUC, CA, CBF, CPR, CPP, ETCO2, ROC, ROSC, rSO2


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 49

P. 360-366 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • Efficacy of topical capsaicin for cannabinoid hyperemesis syndrome in a pediatric and adult emergency department
  • Vivian Kum, Adrienne Bell, Wei Fang, Elizabeth VanWert
| Article suivant Article suivant
  • Flattening the other curve: Reducing emergency department STEMI delays during the COVID-19 pandemic
  • Jesse T.T. McLaren, Ahmed K. Taher, Lucas B. Chartier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.