S'abonner

Value of Dynamic Variation of Impedance Cardiac output in the diagnosis of Heart Failure in emergency department patients with undifferentiated dyspnea. - 29/10/21

Doi : 10.1016/j.ajem.2021.05.042 
Mohamed Amine Msolli, MD a, c, Khaoula Bel Haj Ali, MD a, c, , Adel Sekma, MD a, c, Nasri Bezouich, MD a, c, Imen Trabelsi, PhD c, Imen Gannoun, MSc c, Mohamed Habib Grissa, MD a, c, Hamdi Boubaker, MD a, c, Kaouthar Beltaief, MD a, c, Zohra Dridi, MD d, Riadh Boukef, MD b, Semir Nouira, MD a, c

on behalf of the GREAT Network

a Emergency Department, Fattouma Bourguiba University Hospital, 5000 Monastir, Tunisia 
b Emergency Department, Sahloul University Hospital, 4011 Sousse, Tunisia 
c Research Laboratory LR12SP18, University of Monastir, 5019 Tunisia 
d Cardiology Department, Fattouma Bourguiba University Hospital, 5000 Monastir, Tunisia 

Corresponding author at: Emergency Department and Laboratory Research (LR12SP18), Fattouma Bourguiba University Hospital, 5000 Monastir, Tunisia.Emergency Department and Laboratory Research (LR12SP18)Fattouma Bourguiba University HospitalMonastir5000Tunisia

Abstract

Aim of study

Cardiac output (CO) responses to acute changes in body position and Valsalva maneuver (VM) were proposed to assess cardiac contractile reserve. We investigated the value of sitting position (SP), leg raising (LR), and VM for identifying heart failure (HF) in patients with undifferentiated dyspnea.

Materials and methods

It is a prospective study including patients over 18 years old admitted to the emergency department (ED) for dyspnea. Bioimpedance CO was measured at baseline, under SP, LR, and VM. HF diagnosis was based on clinical assessment, serum levels of brain natriuretic peptide (BNP) and echocardiography findings. Study population was divided into patients with heart failure (HF group) and patients without HF (HF- group). Diagnostic performance of CO change under the three maneuvers was calculated by sensitivity, specificity, likelihood ratio and receiver operating characteristic (ROC) curve.

Results

290 patients were enrolled in the study. The final diagnosis was dyspnea due to congestive heart failure in 147 patients (50.7%). CO change with VM was the most accurate exam in identifying congestive heart failure as the cause of dyspnea with a sensitivity, specificity, positive and negative likelihood ratios of 79%, 60%, 1.97, and 0.36 respectively. Area under ROC curve was 0.62(95% CI, 0.55–0.69), 0.63(95% CI, 0.56–0.69), and 0.70(95% CI, 0.64–0.76) respectively for SP, LR, and VM. In a multivariate analysis, CO change with VM, but not with SP or LR, carried independent diagnostic value (p < 0.001).

Conclusion

the diagnosis of HF can be aided with use of analyzing the effect of VM on non-invasively measured CO among patients admitted to the ED with undifferentiated dyspnea. Diagnostic yield of SP and LR was poor.

Le texte complet de cet article est disponible en PDF.

Keywords : Heart failure, Dyspnea, Diagnosis, Bioimpedance, Cardiac output, Valsalva maneuver


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 49

P. 29-34 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • Risk factors and predictors of QTc prolongation in critically ill Chinese patients
  • Zhidong Qi, Sibo Yang, Ming Li, Jingdong Qu, Qiuyuan Han, Junbo Zheng, Huaiquan Wang
| Article suivant Article suivant
  • Awake intubations in the emergency department: A report from the National Emergency Airway Registry
  • Maria C. Kaisler, Robert J. Hyde, Benjamin J. Sandefur, Amy H. Kaji, Ronna L. Campbell, Brian E. Driver, Calvin A. Brown

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.