S'abonner

The protective effect of tight-fitting powered air-purifying respirators during chest compressions - 29/10/21

Doi : 10.1016/j.ajem.2021.06.012 
Yukari Goto, MD a, , Naruhiro Jingushi, MD a , Hiroaki Hiraiwa, PhD a, b , Hiroaki Ogawa, MD a , Yoshinori Sakai, MD a , Daisuke Kasugai, MD a , Taku Tanaka, PhD a , Michiko Higashi, MD a , Takanori Yamamoto, MD a , Atsushi Numaguchi, MD a
a Department of Emergency and Critical Care, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi 466-8560, Japan 
b Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi 466-8560, Japan 

Corresponding author.

Abstract

Background

Airborne personal protective equipment is required for healthcare workers when performing aerosol-generating procedures on patients with infectious diseases. Chest compressions, one of the main components of cardiopulmonary resuscitation, require intense and dynamic movements of the upper body. We aimed to investigate the protective effect of tight-fitting powered air-purifying respirators (PAPRs) during chest compressions.

Methods

This single-center simulation study was performed from February 2021 to March 2021. The simulated workplace protection factor (SWPF) is the concentration ratio of ambient particles and particles inside the PAPR mask; this value indicates the level of protection provided by a respirator when subjected to a simulated work environment. Participants performed continuous chest compressions three times for 2 min each time, with a 4-min break between each session. We measured the SWPF of the tight-fitting PAPR during chest compression in real-time mode. The primary outcome was the ratio of any failure of protection (SWPF <500) during the chest compression sessions.

Results

Fifty-four participants completed the simulation. Overall, 78% (n = 42) of the participants failed (the measured SWPF value was less than 500) at least one of the three sessions of chest compressions. The median value and interquartile range of the SWPF was 4304 (685–16,191). There were no reports of slipping down of the respirator or mechanical failure during chest compressions.

Conclusions

Although the median SWPF value was high during chest compressions, the tight-fitting PAPR did not provide adequate protection.

Le texte complet de cet article est disponible en PDF.

Highlights

Powered air-purifying respirators (PAPRs) is a type of personal protective equipment.
We measured the protective effect of tight-fitting PAPRs during chest compressions.
Tight-fitting PAPR did not provide adequate protection during chest compression.

Le texte complet de cet article est disponible en PDF.

Keywords : Powered air-purifying respirators, Aerosol-generating procedures, Chest compression

Abbreviations : Coronavirus disease 2019, SARS-CoV-2, AGP, PPE, CPR, NIOSH, PAPR, HCW, APF, FF, SWPF, IQR


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 49

P. 172-177 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • Rates and clinical impact of discordant X-ray and CT imaging in transfers to a pediatric emergency department
  • Jason P. Miller, Ciara Ivanics, Kristina Zalewski, Swati S. Mody, Nirupama Kannikeswaran
| Article suivant Article suivant
  • Association between patients' body mass index and emergency department wait times: A multicenter observational cohort investigation by the reducing disparities increasing equity in emergency medicine (REDEEM) study group
  • Isabella M. Lichen, Venkatesh R. Bellamkonda, Ronna L. Campbell, Sean M. Phelan, Joel R. Anderson, Aidan F. Mullan, Kit Knier, Annie T. Sadosty

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.