Abstract

Background

Assessment of the respiratory changes of the inferior vena cava (IVC) diameter have been investigated as a reliable tool to estimate the volume status in mechanically ventilated and spontaneously breathing patients. Our purpose was to compare the echocardiographic measurements the IVC diameter, stroke volume and cardiac output in different positive pressure ventilation parameters.

Methods

This prospective clinical study with crossover design was conducted in the Intensive Care Unit (ICU). Twenty-five sedated, paralyzed, intubated, and mechanically ventilated patients with volume control mode (CMV) in the ICU due to respiratory failure were included in the study. Positive End-Expiratory Pressure (PEEP) and Tidal Volume (TV) were changed in each patient consecutively (Group A: TV 6 ml/kg, PEEP 5 cmH20, B: TV 6, PEEP 8, C: TV 8, PEEP 5, D: TV 8, PEEP 8) and the changes in vital parameters, central venous pressure (CVP) and ultrasonographic changes in IVC and cardiac parameters were measured. All measures were compared between groups by robust repeated measures ANOVA with trimmed mean.

Results

The respiratory changes of the IVC diameter and echocardiographic parameters showed no significant difference in separate mechanical ventilator settings. Significant difference was found in peak and plateau pressure values among groups (p < 0.05).

Conclusion

The results of our study suggest that IVC related parameters are not affected with different ventilatory settings. Further studies are needed to confirm the reliability of these parameters as a predictor of fluid assessment.

Le texte complet de cet article est disponible en PDF.

Keywords : PEEP, Tidal volume, Inferior vena cava distensibility, Mechanical ventilation


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48

P. 96-102 - octobre 2021 Retour au numéro
Article précédent Article précédent
  • The role of emergency department computed tomography in early acute pancreatitis
  • Matthew R. Lohse, Kazi Ullah, Jesus Seda, Henry C. Thode, Adam J. Singer, Eric J. Morley
| Article suivant Article suivant
  • Examination of ECG characteristics of patients admitted to emergency department with conversive attack
  • Metin Ocak, Mustafa Begenc Tascanov, Zeynep Kemer, ?brahim Halil Yasak, Ülker Fedai

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.