S'abonner

Empirical evidence for safety of mechanical ventilation during simulated cardiopulmonary resuscitation on a physical model - 09/10/21

Doi : 10.1016/j.ajem.2021.06.062 
Leonardo Bugarin Andrade Neumamm, D.Sc. a, b, c, , Alcendino Cândido Jardim-Neto, D.Sc. c, d , Gabriel Casulari Motta-Ribeiro, D.Sc. c
a AmericanCor Hospital, Rio de Janeiro, Brazil 
b Hospital Naval Marcílio Dias, Brazilian Navy, Rio de Janeiro, Brazil 
c Pulmonary Engineering Laboratory, Biomedical Engineering Program (PEB/COPPE), Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil 
d Lung Mechanics Laboratory, Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, USA 

Corresponding author at: Rua Carolina Santos, n 39, apt 405 – Lins de Vasconcelos, Rio de Janeiro, RJ 20720-310, Brazil.Rua Carolina Santos, n 39apt 405 – Lins de VasconcelosRio de JaneiroRJ20720-310Brazil

Abstract

Background

Cardiac arrest is a critical event requiring adequate and timely response in order to increase a patient's chance of survival. In patients mechanically ventilated with advanced airways, cardiopulmonary resuscitation (CPR) maneuver may be simplified by keeping the ventilator on. This work assessed the response of an intensive care mechanical ventilator to CPR using a patient manikin ventilated in three conventional modes.

Methods

Volume-controlled (VCV), pressure-controlled (PCV) and pressure regulated volume-controlled (PRVC) ventilation were applied in a thorax physical model, with or without chest compressions. The mechanical ventilator was set with inspiratory time of 1.0 s, ventilation rate of 10 breaths/min, positive end-expiratory pressure of 0 cmH2O, FiO2 of 1.0, target tidal volume of 600 mL and trigger level of −20 cmH2O. Airway opening pressure and ventilatory flow signals were continuously recorded.

Results

Chest compression resulted in increased airway peak pressure in all ventilation modes (p < 0.001), especially with VCV (137% in VCV, 83% in PCV, 80% in PRVC). However, these pressures were limited to levels similar to release valves in manual resuscitators (~60 cmH2O). In pressure-controlled modes tidal/min volumes decreased (PRVC = 11%, p = 0.027 and PCV = 12%, p < 0.001), while still within the variability observed during bag-valve-mask ventilation. During VCV, variation in tidal/min volumes were not significant (p = 0.140). Respiratory rate did not change with chest compression.

Conclusions

Volume and pressure ventilation modes responded differently to chest compressions. Yet, variation in delivered volume and the measured peak pressures were within the reported for the standard bag-valve-mask system.

Le texte complet de cet article est disponible en PDF.

Keywords : Cardiopulmonary resuscitation, Mechanical ventilation, Cardiac arrest, Simulation


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48

P. 312-315 - octobre 2021 Retour au numéro
Article précédent Article précédent
  • The pragmatic use of industrial elastomeric facemasks in health care practice during the COVID-19 pandemic
  • Kathleen McMahon, Donald Jeanmonod, Ronald Check, Leah Rivard, Vamsi Balakrishnan, Brian Kelly, Jonathan Pester, Rebecca Jeanmonod
| Article suivant Article suivant
  • Periodontal disease and myocardial infarction risk: A meta-analysis of cohort studies
  • Xiaoru Qin, Yifeng Zhao, Yuxuan Guo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.