S'abonner

Accuracy of point-of-care ultrasound for determining the adequacy of pediatric forearm fracture reductions - 09/10/21

Doi : 10.1016/j.ajem.2021.05.021 
Nihan Şık a, Ali Öztürk a, Mustafa Can Koşay b, Durgül Yılmaz a, Murat Duman a,
a Division of Pediatric Emergency Care, Department of Pediatrics, Dokuz Eylul University Faculty of Medicine, Izmir, Turkey 
b Department of Orthopedics and Traumatology, Dokuz Eylul University Faculty of Medicine, Izmir, Turkey 

Corresponding author.

Abstract

Background

The objective of the present study was to the determine the accuracy of point-of-care ultrasound (POCUS) in assessing closed reduction (CR) of pediatric forearm fractures in a pediatric emergency setting.

Methods

After determination of the need for CR using X-ray images by an orthopedic consultant, POCUS examinations were performed just before and after the reduction attempt. The transducer was positioned longitudinally over the dorsal, volar, and lateral surfaces of the radius and ulna to view the fracture site. The presence of angulation, displacement, or bayonetting of the fracture fragments was recorded. The adequacy of realignment according to the POCUS and the orthopedic consultant's final determination were recorded.

Results

Sixty-two patients were enrolled in the study and 96 bones were evaluated. The sensitivity and specificity of POCUS for adequacy of CR were 95.8% [95% confidence interval (CI): 88.3–99.1)] and 95.8% (95% CI: 78.8–99.8), the positive predictive value was 98.5% (95% CI: 91.0–99.7), and the negative predictive value was 88.4% (95% CI: 71.6–95.8). The corresponding positive and negative likelihood ratios were 23 (3.37–156.77) and 0.04 (0.01–0.12). There was high agreement between POCUS and X-ray images for predicting adequacy of CR [κ: 0.892 (±0.053)]. There was also a significant correlation between POCUS and X-ray measurements of angulation and displacement performed before and after CR, respectively (p < 0.001).

Conclusion

Our study has reported the successful use of POCUS for the management of pediatric forearm fractures in a pediatric emergency department. Point-of-care ultrasound can minimize radiation exposure and appears to be an alternative and accurate tool for reduction attempts.

Le texte complet de cet article est disponible en PDF.

Highlights

Point-of-care ultrasonography (POCUS) is increasingly available in pediatric emergency settings in recent years.
There was high agreement between POCUS and radiograph images for predicting adequacy of closed reduction.
There was high agreement between POCUS and radiograph images for predicting adequacy of closed reduction.

Le texte complet de cet article est disponible en PDF.

Keywords : Children, Forearm fracture, Ultrasound, Reduction

Abbreviations : CR, ALARA, POCUS, ED, SD, IQR, PPV, NPV, CI


Plan


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48

P. 243-248 - octobre 2021 Retour au numéro
Article précédent Article précédent
  • The impact of emergency department observation units on a health system
  • Michael Perry, Nicole Franks, Stephen R. Pitts, Tim P. Moran, Anwar Osborne, Dane Peterson, Michael A. Ross
| Article suivant Article suivant
  • Empiric aztreonam is associated with increased mortality compared to beta-lactams in septic shock
  • Rupal K. Jaffa, John Hammer, Leigh Ann Medaris, William E. Anderson, Alan C. Heffner, Kelly E. Pillinger

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.