S'abonner

Use of continuous glucose monitoring in obesity research: A scoping review - 06/10/21

Doi : 10.1016/j.orcp.2021.08.006 
Elizabeth Hegedus a, Sarah-Jeanne Salvy b, Choo Phei Wee c, Monica Naguib a, Jennifer K. Raymond a, D. Steven Fox d, Alaina P. Vidmar a,
a Children’s Hospital Los Angeles and Keck School of Medicine of USC, Center for Endocrinology, Diabetes and Metabolism, Los Angeles, CA, United States 
b Cancer Research Center on Health Equity, Cedars-Sinai Medical Center, West Hollywood, CA, United States 
c Southern California Clinical and Translational Science Institute, Department of Preventive Medicine, Keck School of Medicine, Los Angeles, CA, United States 
d Department of Pharmaceutical and Health Economics, School of Pharmacy of the University of Southern California, Los Angeles, CA, United States 

Corresponding author at: 4650 Sunset Boulevard, Mailstop #61, Los Angeles, CA 90027, United States.4650 Sunset BoulevardMailstop #61Los AngelesCA90027United States

Highlights

Continuous glucose monitoring is tolerated in obesity research.
Standard deviation is the most common glycemic variability metric.
Continuous glucose monitoring can provide biofeedback and monitor dietary adherence.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

This scoping review provides a timely synthesis of the use of continuous glucose monitoring in obesity research with considerations to adherence to continuous glucose monitor devices and metrics most frequently reported.

Methods

This scoping review was conducted adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) checklist. Eligible studies (n = 31) evaluated continuous glucose monitor use in research on participants, of all ages, with overweight or obesity.

Results

Reviewed studies varied in duration from one to 84 days (mean: 8.74 d, SD 15.2, range 1–84 d) with 889 participants total (range: 11–118 participants). Across all studies, the mean percent continuous glucose monitor wear time (actual/intended wear time in days) was 92% (numerator – mean: 266.1 d, SD: 452, range: 9–1596 d/denominator – mean: 271.6 d, SD: 451.5, range: 9–1596 d). Continuous glucose monitoring was utilized to provide biofeedback (n = 2, 6%), monitor dietary adherence (n = 2, 6%), and assess glycemic variability (n = 29, 93%). The most common variability metrics reported were standard deviation (n = 19, 62%), area under the curve (n = 12, 39%), and glycemic range (n = 12, 39%).

Conclusions

Available evidence suggests that continuous glucose monitoring is a well-tolerated and versatile tool for obesity research in pediatric and adult patients. Future investigation is needed to substantiate the feasibility and utility of continuous glucose monitors in obesity research and maximize comparability across studies.

Le texte complet de cet article est disponible en PDF.

Abbreviations : BMI, zBMI, CI, CGM, GV, MeSH, %BMIp95

Keywords : Continuous glucose monitor, Obesity, Overweight, Adherence


Plan


© 2021  Asia Oceania Association for the Study of Obesity. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15 - N° 5

P. 431-438 - septembre 2021 Retour au numéro
Article précédent Article précédent
  • The association of general obesity, central obesity and visceral body fat with the risk of gestational diabetes mellitus: Evidence from a systematic review and meta-analysis
  • Sura M. Alwash, H. David McIntyre, Abdullah Mamun
| Article suivant Article suivant
  • Effect of long-term weight gain on the risk of breast cancer across women’s whole adulthood as well as hormone-changed menopause stages: A systematic review and dose–response meta-analysis
  • Yu Hao, Menglu Jiang, Yunqi Miao, Xu Li, Can Hou, Xiaofan Zhang, Hui Chen, Xiaorong Zhong, Jiayuan Li

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.