S'abonner

Technical Validation and Usability of a Portable Ultrasound-Based System for Carotid Assessment of Vascular Ageing: A Pilot Study - 28/09/21

Doi : 10.1016/j.hlc.2021.06.530 
Martina Francesconi, Msc a, b, Maria Raffaella Martina, MSc, PhD b, Silvia Armenia, MSc a, Andrea Buzzelli, MSc b, Gregorio Di Franco, MD, PhD c, Vincenzo Gemignani, MSc b, Elisabetta Bianchini, MSc, PhD b, , 1 , Rosa Maria Bruno, MD, PhD d, 1
a Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy 
b Institute of Clinical Physiology, Italian National Research Council, Pisa, Italy 
c General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy 
d INSERM U970 Paris Cardiovascular Research Centre – PARCC, Université de Paris, and AP-HP, Pharmacology Unit, Hôpital Européen Georges Pompidou, Paris, France 

Corresponding author at: Institute of Clinical Physiology, Italian National Research Council, Pisa, Italy

Abstract

Objective

The objective of this work was to investigate technical validation and usability of an innovative, technically simple, easy-to-use, and portable integrated system to assess carotid function and structure by ultrasound.

Methods

The studied system integrated a hardware (the Interson SP-L01 embedded ultrasound probe [Interson, Pleasanton, CA, USA]) and a software measuring the instantaneous diameter of the carotid artery in real-time from B-mode ultrasound image sequences (Carotid Studio, by Quipu Srl [Pisa, Italy]). Technical validation was evaluated by intra-operator reproducibility of two measurements acquired by an expert operator, and agreement with state-of-the-art technique (Mylab25 by Esaote SpA [Genova, Italy], Carotid Studio 4.3 by Quipu Srl) was evaluated in laboratory settings in 12 healthy volunteers; usability of the portable integrated system was investigated by administering questionnaires to users and the results were reported with scores based on a five-point scale.

Results

Twelve (12) healthy volunteers (five men, mean age 44.5±13.6 years, free of cardiovascular disease or risk factors), were recruited. Agreement with state-of-the-art technique was satisfactory, with no significant bias. Coefficient of variation (intra-operator reproducibility) was 3.2% (2.5% SD) for intima-media thickness, 0.9% (0.7% SD) for diameter, and 2.5% (2.2% SD) for distension. Usability questionnaires showed an overall positive judgement of the integrated system with respect to the traditional one, obtaining an average score greater than 4 (on a five-point scale).

Conclusions

A portable, innovative prototype to easily assess ultrasound carotid parameters of vascular ageing was successfully designed, developed, and demonstrated to be comparable with state-of-the art technique. Usability was also satisfactory.

Le texte complet de cet article est disponible en PDF.

Keywords : Carotid IMT, Carotid distensibility, Ultrasound, Portable system


Plan


© 2021  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 11

P. 1734-1743 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • The Association Between Contrast-Enhanced Ultrasound and Near-Infrared Spectroscopy-Derived Measures of Calf Muscle Microvascular Responsiveness in Older Adults
  • Grace M. Young, Digby Krastins, David Chang, Jeng Lam, Jing Quah, Tony Stanton, Fraser Russell, Kim Greaves, Yuri Kriel, Christopher D. Askew
| Article suivant Article suivant
  • Comparison of Different Cardiovascular Risk Score and Pulse Wave Velocity-Based Methods for Vascular Age Calculation
  • Helga Gyöngyösi, Beáta K?rösi, Dóra Batta, Zsófia Nemcsik-Bencze, Andrea László, András Tislér, Orsolya Cseprekál, Péter Torzsa, Dániel Eörsi, János Nemcsik

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.