S'abonner

Sinus venosus atrial septal defect in adults: Where we are and where we go? Initial experience of percutaneous repair - 14/08/21

Doi : 10.1016/j.acvdsp.2021.06.102 
Clément Batteux , Philippe Brenot, Bastien Provost, Vlad Ciobotaru, Sarah Cohen, Isabelle Van Aerschot, Jied Laribi, Emmanuelle Fournier, Jérôme Petit, Joy Zoghbi, Meriem Mostefa-Kara, Nicolas Combes, Alice Maltret, Régine Roussin, Emre Belli, Sébastien Hascoet
 Hôpital Marie-Lannelongue, département médico-chirurgical des cardiopathies pédiatrique congénitales, M3C, GHPSJ, 133, avenue de la Résistance, 92350 Le Plessis-Robinson, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Percutaneous repair of sinus venosus atrial septal defect (SV ASD) has emerged with promising preliminary results. We sought to expose the modified management strategy for this pathology in our tertiary center.

Methods

Since March 2020, date of the first percutaneous procedure, therapeutic strategy for SV ASD patients has changed and was based on cardiac CT and 3D STL models for anatomic analysis in all patients. Flow-MRI and 3D printing were produced in selected cases to upgrade anatomic understanding and strategy decision (Fig. 1). Forecast success and issues were studied based on anatomic findings. Safety, efficiency and follow-up with both technics were noticed for decision making.

Results

From March 2020 to March 2021, 18 adults patients were reffered for SV ASD closure. Median age was 47 years old (18 to 84years old) (Fig. 2). Surgical correction was performed in 5 patients (27.8%) using patch baffle (3/5) or Warden technique (2/5). Length of hospital stay was 8±3days and no major event occurred. Immediate surgical results were excellent in all cases.

Percutaneous closure was performed in 4 cases (22.2%). Procedures were simulated on 3D printed models in all cases. Procedures were guided using transesophageal echocardiography, fusion between fluoroscopy and echography, and fusion between CT scan and fluoroscopy.

One residual shunt occurred but disappeared on the cath control at month 3. Stents used were covered CP10Z80, CP10Z70, CP 10Z60, and Bentley begraft aortic in one case. In two cases, covered stents were stabilized by adding bare metal stents. All 4 patients were discharged at day 3 with acetylsalicylic acid therapy.

Eight of nine pending patients for percutaneous closure will be planned in 2021.

Conclusion

Percutaneous management of SVASD was safe and efficient in selected cases. Pre-procedural multimodality imaging including 3D modeling appears to be a necessary condition for a tailored patient's selection.

Le texte complet de cet article est disponible en PDF.

Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 4

P. 333-334 - septembre 2021 Retour au numéro
Article précédent Article précédent
  • Cardiotoxicity of perioperative chemotherapy for neublastoma in pediatric visceral surgery
  • K. El Fakhr, K. Damaan, S. Yahya, W. Aissaoui, S. Kalouch, K. Yaqini, A. Chlilek

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.