S'abonner

Medtronic microvascular plug™: A multipotent device for transcatheter occlusions in children with congenital heart disease - 14/08/21

Doi : 10.1016/j.acvdsp.2021.06.076 
Raymond N. Haddad 1, , Damien Bonnet 1, 2, Sophie Malekzadeh-Milani 1
1 M3C-Necker, hôpital universitaire Necker-Enfants–malades, AP–HP, Paris, France 
2 Université de Paris, Paris, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Objectives

To evaluate our experience with the MVP™ Microvascular Plug system for embolizations of vascular abnormalities in children with congenital heart diseases (CHD).

Background

The MVP™ is a recent valuable addition to the armamentarium for vascular embolization. Data on its use in pediatric and congenital cardiology is scarce.

Methods

Medical records and catheterization reports of all children with CHD who had attempted transcatheter embolizations with MVP™ between April 2015 and September 2020 were retrospectively reviewed. Type of lesions, immediate procedural outcomes, and follow-up data were assessed.

Results

A total of 153 patients underwent 172 procedures during which 240 vessel embolizations using 259 MVP™ were attempted. Median age and weight were 34.9months and 12.5kg, respectively. Two devices were deployed at the same site in 14 cases. Seven devices were removed before release. Procedural success rate was 99.2%. Target vessels anomalies were systemic arteries (n=163), patent arterial duct (n=26), venous (n=45), and coronaro-cameral fistulae (n=6). Mean vessel diameter was 3.3±1.1mm (1.4 to 9mm). A detailed device selection chart according to vessel type and diameter was presented based on our experience (Table 1). Complete closure rate was 94.4% at the end of the procedure and increased up to 100% across follow-up. Major complications were limited to one device migration requiring surgery and 4 embolizations treated with percutaneous retrieval.

Conclusions

Safety and efficacy of abnormal vessel embolization using the MVP™ were demonstrated in the largest cohort of children with CHD and in a variety of applications. The major advantages of the MVP™ are smooth delivery with high procedural flexibility leading to immediate and stable closure with a single device in most cases, potentially reducing duration, radiation exposure, and decreasing the size of the sheath used in small children.

Le texte complet de cet article est disponible en PDF.

Keywords : Congenital heart defect, Device closure, Microvascular plug, Vessel embolizations


Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 4

P. 318 - septembre 2021 Retour au numéro
Article précédent Article précédent
  • Preliminary experience with the new Amplatzer™ Trevisio™ delivery system in transcatheter atrial septal defect closures in children
  • Raymond N. Haddad, Diala Khraiche, Damien Bonnet, Mathilde Meot, Sophie Malekzadeh-Milani
| Article suivant Article suivant
  • Retrospective descriptive study about causes of death in children with heart disease, between 2010 and 2020
  • Daphné Madec, Damien Bonnet

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.