S'abonner

Evaluation of image quality and radiation dose with prospective ECG-gated 80 multi-slice CT scan in 182 consecutive children examinations with congenital heart disease - 14/08/21

Doi : 10.1016/j.acvdsp.2021.06.057 
Pauline De Cambourg, MD 1 : writer, Thomas Senage, MD 2 : data manager, Hatem Nécib 3 : radiophysicist, Karine Warin Fresse, MD 4,  : reviewer
1 Department of paediatric imaging, centre hospitalier universitaire de Nantes, 38, boulevard Jean-Monnet, 44093 Nantes cedex 1, France 
2 Department of thoracic surgery, centre hospitalier universitaire de Nantes, hôpital Laënnec, boulevard Jacques-Monod – Saint-Herblain, 44093 Nantes cedex 1, France 
3 Department of radiology, centre hospitalier universitaire de Nantes, 1, place Alexis-Ricordeau, 44093 Nantes cedex 1, France 
4 Department of cardiovascular radiology, centre hospitalier universitaire de Nantes, hôpital Laënnec, boulevard Jacques-Monod – Saint-Herblain, 44093 Nantes cedex 1, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Computed tomography angiography (CTA) is a reliable imaging tool to evaluate children congenital heart disease (CHD) but requires radiation exposure. This study aims to investigate image quality and radiation dose with a prospective electrocardiogram (ECG)-gated 80 multi-slice CTA, in 182 consecutive children examinations with CHD.

Materials and methods

In total, 182 consecutive examinations performed with a prospective ECG-gated 80 multi-slice CTA from March 2016 to December 2017 in Nantes university hospital were retrospectively analyzed. Radiation dose was assessed by dose length product (DLP) and effective dose (E). Objective quality image was assessed by contrast to noise ratio (CNR). Subjective quality image was assessed by two radiologists with a 10-point scale evaluating visualization of coronary arteries. Correlation between quality image, radiation dose, age, weight, heart rate was analyzed.

Results

DLP and E were 29.3±15.5mGy.cm and 0.6±0.2mSv, respectively. Agreement between radiologists in assessment of subjective image quality was 0.79. Subjective image quality score was significantly better (P<0.01) with higher age, weight, DLP and lower heart rate in univariate analysis. CNR was significantly lower with increasing weight and DLP (P<0.05) but there was no correlation between CNR and age and heart rate.

Conclusion

Prospective ECG-gated 80 multi-slice CTA is performing for the evaluation of children CHD with good image quality and low radiation dose. Visualization of small structures is better when age and weight increase, heart rate decreases and when radiation dose is more important. CNR evolves in the opposite side to subjective image quality score. It seems less appropriate to assess image quality from clinical viewpoint of the radiologist.

Le texte complet de cet article est disponible en PDF.

Keywords : Congenital heart disease, CT angiography, Prospective ECG-gated, Image quality, Radiation dose


Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 4

P. 304 - septembre 2021 Retour au numéro
Article précédent Article précédent
  • Late myocardial infarct in pulmonary atresia and intact ventricular septum: A must-know complication!
  • Marie Wilkin, Edouard Aries, Caroline Ovaert
| Article suivant Article suivant
  • Sacubitril/Valsartan for heart failure in adults with systemic right ventricle: A single center safety and efficacy experience
  • Claire Massardier, Christine Houde, Jean-Marc Côté, Christian Drolet, Laurence Vaujois, Philippe Chetaille, Mathieu Bernier, Mario Senechal, Elisabeth Bedard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.