S'abonner

Patient Tolerability With Office Transperineal Biopsy Using a Reusable Needle Guide - 11/08/21

Doi : 10.1016/j.urology.2021.05.018 
Stephen Wertheimer, Jeff Budzyn, Sara Perkins, Alex Borchert, Craig Rogers, Amit Patel
 Vattikuti Urology Institute, Henry Ford Health System, Detroit, MI 

Address correspondence to: Amit Patel, MD, Vattikuti Urology Institute, Henry Ford Health System, 2799 W Grand Blvd, Detroit, MI 48202-2689.Vattikuti Urology InstituteHenry Ford Health System2799 W Grand BlvdDetroitMI48202-2689.

Résumé

Objective

Transrectal ultrasound-guided (TRUS) prostate biopsy is associated with a 1%-5% risk of severe sepsis, despite the use of prophylactic antibiotics. Recent studies have demonstrated the feasibility of transperineal (TP) prostate biopsy in the outpatient setting under local anesthetic (LA). We demonstrate the safety, efficacy, and tolerability of our technique for performing TP biopsy under LA in the clinic setting using a reusable needle guide.

Methods

A biplanar ultrasound probe with an attached adjustable, reusable needle guide was evaluated for transperineal biopsy. A 17 gauge x 10 cm coaxial needle is attached to the needle guide. The skin is infiltrated, bilaterally, approximately 2 cm anterolateral to the anal verge with 1% lidocaine using a 25 gauge needle. A deeper prostatic block is then performed using a 20 gauge spinal needle. Administration of the anesthetic is delivered to the musculature of the pelvic floor, superficial-to-deep. Prostate samples are obtained using an 18 gauge x 25cm biopsy gun. All biopsies on a side can be obtained utilizing a single perineal skin puncture site.

Patients who underwent office TP biopsy after May 2019 also completed a 10-item patient experience questionnaire regarding pain or discomfort experienced during the procedure.

Results

In 2019, a total of 74 patients underwent office TP prostate biopsy under local anesthesia using a reusable needle guide, while 564 underwent office TRUS biopsy. Prostate biopsy was positive for malignancy in 58.1% of TP patients vs 57.6% in TRUS patients (P = .93). TP biopsy had a lower utilization of prophylactic antibiotics compared to TRUS biopsy: 33.8% vs 99.5% (P < .001), yet there were no admissions, UTI, or sepsis for TP patients, compared to 6 admissions (1.1%) for TRUS biopsy (P = .01)). The mean VAS score ± SD for pain or discomfort caused by the overall office TP biopsy was 3.68 ± 1.96.

Conclusion

We demonstrate that office TP biopsy under LA with a reusable needle guide can be safely introduced with equivalent cancer detection rates whilst nearly eliminating the risk of urinary sepsis. This was achieved while also significantly reducing the use of prophylactic antibiotics. The procedure was well tolerated, with the most common complaint being local infiltration of anesthetic. We believe that office TP biopsy under LA can be performed with good patient tolerability, as almost 94% of patients were willing to undergo the procedure again. There is also the potential for reduction in overall cost with the use of a reusable needle guide.

Le texte complet de cet article est disponible en PDF.

Plan


 Conflict of Interest: None.


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 154

P. 339-341 - août 2021 Retour au numéro
Article précédent Article précédent
  • Rectourethral Fistula Repair Using Robotic Transanal Minimally Invasive Surgery (TAMIS) Approach
  • Kevin J Hebert, Nimesh Naik, Ahmed Allawi, Scott R Kelley, Kevin T Behm, Boyd R Viers
| Article suivant Article suivant
  • Salvage Enbloc Thulium Fiber Laser Enucleation of Prostate for Giant Prostatomegaly After Prostatic Urethral Lift
  • Nicholas A. Smith, Jonathan E. Katz, Hemendra N. Shah

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.