S'abonner

Performance and operational feasibility of antigen and antibody rapid diagnostic tests for COVID-19 in symptomatic and asymptomatic patients in Cameroon: a clinical, prospective, diagnostic accuracy study - 29/07/21

Doi : 10.1016/S1473-3099(21)00132-8 
Yap Boum, PhD a, b, , Karl Njuwa Fai, MD a, Birgit Nikolay, PhD c, Akenji Blaise Mboringong, MD d, Lisa M Bebell, MD e, Mark Ndifon, MSc a, Aristide Abbah, MD b, Rachel Essaka, MSc f, Lucrèce Eteki, MPH a, Francisco Luquero, PhD c, Céline Langendorf, MD c, Nicole Fouda Mbarga, MD g, Rene Ghislain Essomba, PhD d, Bongkiyung Donald Buri, MSc a, Tchoula Mamiafo Corine, MSc a, Bertrand Tchualeu Kameni, MSc d, Nadia Mandeng, MD b, Mahamat Fanne, MD b, Anne-Cécile Zoung-Kani Bisseck, MD h, Clement B Ndongmo, PhD i, Sara Eyangoh, PhD j, Achta Hamadou, MD j, Jean Patrick Ouamba, MD g, Modeste Tamakloé Koku, MD g, Richard Njouom, PhD j, Okomo Marie Claire, PhD d, Linda Esso, MD b, Emilienne Epée, MD b, Georges Alain Etoundi Mballa, MD b
a Epicentre, Yaoundé, Cameroon 
b Public Health Emergency Operation Center, Ministry of Public Health, Yaoundé, Cameroon 
c Epicentre, Paris, France 
d National Public Health Laboratory, Yaoundé, Cameroon 
e Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA 
f Laboratoire du Lac, Yaoundé, Cameroon 
g Médecins Sans Frontières Suisse, Yaoundé, Cameroon 
h Division de la Recherche Opérationnelle en Santé, Ministère de la Santé Publique, Yaoundé, Cameroon 
i Centers for Disease Control and Prevention, Atlanta, GA, USA 
j Centre Pasteur du Cameroon, Yaoundé, Cameroon 

* Correspondence to: Dr Yap Boum, Epicentre, BP 12069 Yaoundé, Cameroon Epicentre Yaoundé BP 12069 Cameroon

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Background

Real-time PCR is recommended to detect SARS-CoV-2 infection. However, PCR availability is restricted in most countries. Rapid diagnostic tests are considered acceptable alternatives, but data are lacking on their performance. We assessed the performance of four antibody-based rapid diagnostic tests and one antigen-based rapid diagnostic test for detecting SARS-CoV-2 infection in the community in Cameroon.

Methods

In this clinical, prospective, diagnostic accuracy study, we enrolled individuals aged at least 21 years who were either symptomatic and suspected of having COVID-19 or asymptomatic and presented for screening. We tested peripheral blood for SARS-CoV-2 antibodies using the Innovita (Biological Technology; Beijing, China), Wondfo (Guangzhou Wondfo Biotech; Guangzhou, China), SD Biosensor (SD Biosensor; Gyeonggi-do, South Korea), and Runkun tests (Runkun Pharmaceutical; Hunan, China), and nasopharyngeal swabs for SARS-CoV-2 antigen using the SD Biosensor test. Antigen rapid diagnostic tests were compared with Abbott PCR testing (Abbott; Abbott Park, IL, USA), and antibody rapid diagnostic tests were compared with Biomerieux immunoassays (Biomerieux; Marcy l’Etoile, France). We retrospectively tested two diagnostic algorithms that incorporated rapid diagnostic tests for symptomatic and asymptomatic patients using simulation modelling.

Findings

1195 participants were enrolled in the study. 347 (29%) tested SARS-CoV-2 PCR-positive, 223 (19%) rapid diagnostic test antigen-positive, and 478 (40%) rapid diagnostic test antibody-positive. Antigen-based rapid diagnostic test sensitivity was 80·0% (95% CI 71·0–88·0) in the first 7 days after symptom onset, but antibody-based rapid diagnostic tests had only 26·8% sensitivity (18·3–36·8). Antibody rapid diagnostic test sensitivity increased to 76·4% (70·1–82·0) 14 days after symptom onset. Among asymptomatic participants, the sensitivity of antigen-based and antibody-based rapid diagnostic tests were 37·0% (27·0–48·0) and 50·7% (42·2–59·1), respectively. Cohen’s κ showed substantial agreement between Wondfo antibody rapid diagnostic test and gold-standard ELISA (κ=0·76; sensitivity 0·98) and between Biosensor and ELISA (κ=0·60; sensitivity 0·94). Innovita (κ=0·47; sensitivity 0·93) and Runkun (κ=0·43; sensitivity 0·76) showed moderate agreement. An antigen-based retrospective algorithm applied to symptomatic patients showed 94·0% sensitivity and 91·0% specificity in the first 7 days after symptom onset. For asymptomatic participants, the algorithm showed a sensitivity of 34% (95% CI 23·0–44·0) and a specificity of 92·0% (88·0–96·0).

Interpretation

Rapid diagnostic tests had good overall sensitivity for diagnosing SARS-CoV-2 infection. Rapid diagnostic tests could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and onward viral transmission.

Funding

Médecins Sans Frontières WACA and Médecins Sans Frontières OCG.

Translations

For the French and Spanish translations of the abstract see Supplementary Materials section.

Le texte complet de cet article est disponible en PDF.

Plan


© 2021  Elsevier Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 21 - N° 8

P. 1089-1096 - août 2021 Retour au numéro
Article précédent Article précédent
  • Detective doctor decodes AIDS mystery
  • Vijay Shankar Balakrishnan
| Article suivant Article suivant
  • Prioritising COVID-19 vaccination in changing social and epidemiological landscapes: a mathematical modelling study
  • Peter C Jentsch, Madhur Anand, Chris T Bauch

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.