Introduction: Excessive minute ventilation during cardiac arrest may cause lung injury and decrease the effectiveness of cardiopulmonary resuscitation (CPR). However, little is known about how clinicians deliver tidal volumes and respiratory rates during CPR. Methods: In this cross-sectional study, licensed practitioners attending an American Heart Association (AHA) Advanced Cardiac Life Support (ACLS) course performed CPR and manual ventilation on a high-fidelity simulator during the megacode portion of the course. Delivered tidal volumes and respiratory rates were measured on a monitor. During the first scenario, results were not displayed to participants, but were displayed during the second scenario. Results: Fifty-two clinicians participated in this study. Average height was 169 (157,178) cm. Pre-monitor display tidal volumes delivered were larger in male participants compared to female participants (684.6 ± 134.4 vs 586.7 ± 167.6 ml, P = 0.05). Those using medium-sized gloves delivered smaller tidal volumes than those using small or large gloves. Twenty-two (42.3%) delivered tidal volume in the range of 5–8 ml/kg of predicted body weight for the simulation manikin, and 35 (67.3%) delivered tidal volumes with >20% variability among breaths. All participants met the target respiratory rate around 10 breaths/min. Conclusion: Tidal volume delivery varied greatly during manual ventilation and fewer than half participants delivered tidal volume at 5–8 ml/kg to the manikin. Sex and glove size appeared to impact tidal volume delivery when the participants were unaware of what they were delivering. Participants were able to meet the target respiratory rate around 10 without audio or visual feedback.

Le texte complet de cet article est disponible en PDF.

Keywords : Manual ventilation, Tidal volume, Respiratory rate, Resuscitation


Plan


© 2020  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 45

P. 446-450 - juillet 2021 Retour au numéro
Article précédent Article précédent
  • The Iowa less aggressive protocol: A mixed-methods study on the novel treatment protocol of atrial fibrillation
  • Benjamin E. Christians, Christopher J. Solie, Morgan B. Swanson, Karisa K. Harland, Catherine Fairfield, Kelli L. Wallace, Nicholas M. Mohr
| Article suivant Article suivant
  • Racial/ethnic disparities in COVID-19 disease burden & mortality among emergency department patients in a safety net health system
  • Nana-Yaa Misa, Berenice Perez, Kellie Basham, Essence Fisher-Hobson, Brittany Butler, Kolette King, Douglas A.E. White, Erik S. Anderson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.