Imaging in chronic rhinosinusitis: A systematic review of MRI and CT diagnostic accuracy and reliability in severity staging - 03/06/21

Doi : 10.1016/j.neurad.2021.01.010 
Tomislav Gregurić a, Emmanuel Prokopakis b, Ioannis Vlastos b, Maria Doulaptsi b, Cemal Cingi c, Andro Košec d, , Dijana Zadravec a, Livije Kalogjera d
a Department of Diagnostic and Interventional Radiology, University Hospital Centre “Sestre milosrdnice”, Zagreb, Croatia 
b Department of Otorhinolaryngology, University of Crete School of Medicine, Heraklion, Crete, Greece 
c Department of Otolaryngology, Head and Neck Surgery, Eskişehir Osmangazi University, Eskisehir, Turkey 
d Department of ORL/Head and Neck Surgery, Zagreb School of Medicine, University Hospital Centre “Sestre milosrdnice”, Zagreb, Croatia 

Corresponding author at: Department of Otorhinolaryngology and Head and Neck Surgery, School of Medicine, University of Zagreb, University Hospital Center Sestre milosrdnice, Zagreb, Croatia.Department of Otorhinolaryngology and Head and Neck SurgerySchool of MedicineUniversity of ZagrebUniversity Hospital Center Sestre milosrdniceZagrebCroatia

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 1
Vidéos 0
Autres 0

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

CT is the most commonly used imaging technique for the severity staging of CRS
This review included 21 studies concerned with CT and/or MRI imaging in CRS diagnostic accuracy and/or severity staging
MRI may be a complementary staging tool when repeated examinations are required
MRI may be utilized as a staging tool, using the same staging systems as with CT

Le texte complet de cet article est disponible en PDF.

Abstract

Background

Computerized tomography (CT) severity scores are frequently used as an objective staging tool in chronic rhinosinusitis (CRS). Magnetic resonance imaging (MRI) has also been proposed as a valid option in CRS imaging.

Purpose

The aim of this systematic review was to briefly present the recent developments on sinus imaging utilized in clinical practice with regard to diagnostic accuracy of imaging and severity staging in CRS according to evidence-based medicine (EBM) principles.

Material and Methods

This review paper has been assembled following PRISMA guidelines. A PubMed and Scopus (EMBASE) search using CRS, „severity staging“, „diagnostic accuracy “and „imaging “resulted with 80 results. Of these, only 12 (59%) contained original data, constituting the synthesis of best-quality available evidence.

Results

CT is the most commonly used imaging technique for the severity staging of CRS, but a question of higher cumulative radiation dose should be taken into consideration when repeating CT examinations in evaluating treatment efficacy. MRI may be a complementary diagnostic and staging tool, especially when repeated examinations are required, or when paediatric CRS patients are evaluated. The severity staging system may be improved to better correlate with subjective scores.

Conclusions

MRI may be utilized as a staging tool with comparable diagnostic accuracy, using the same staging systems as with CT examinations.

Le texte complet de cet article est disponible en PDF.

Keywords : CT scan, Magnetic resonance, Tomography, cone-beam computed, Nasal sinuses, Transnasal endoscopic surgery


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48 - N° 4

P. 277-281 - juin 2021 Retour au numéro
Article précédent Article précédent
  • Should CT angiography of the supra-aortic arteries be performed systematically following attempted suicide by hanging?
  • C. Ribaute, J. Darcourt, S. Patsoura, M. Ferrier, Z. Meluchova, R. Gramada, I. Catalaa, S. Charpentier, B. Riu, S. Silva, C. Cognard, F. Bonneville
| Article suivant Article suivant
  • Using mathematics in MRI data management for glioma assesment
  • A. Perrillat-Mercerot, C. Guillevin, A. Miranville, R. Guillevin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.