S'abonner

Does change in language change the properties of a shortened score previously validated in its complete version? Validation of the French versions of the HOOS-12 and KOOS-12 scores in primary knee and hip arthroplasties - 27/04/21

Doi : 10.1016/j.otsr.2021.102824 
Sophie Putman a, b, c, , Henri Migaud a, b, Gilles Pasquier a, b, Julien Girard a, b, Cristian Preda e, f, Alain Duhamel c, d
a Université de Lille, CHU de Lille, ULR 4490, Hôpital Salengro, 59000 Lille, France 
b Département universitaire de chirurgie orthopédique et traumatologique, hôpital Roger-Salengro, CHU de Lille, place de Verdun, 59037 Lille, France 
c Université de Lille, CHU de Lille, EA 2694–Metrics: évaluation des technologies de santé et des pratiques médicales, 59000 Lille, France 
d CHU de Lille, unité de methodologie et biostatistiques, 59000 Lille, France 
e Laboratory of mathematics Paul-Pain-Levé, UMR CNRS 8524, University of Lille, Lille, France 
f Lille catholic hospitals, Biostatistics department delegation for clinical research and innovation, Lille Catholic University, Lille, France 

Corresponding author at: Département universitaire de chirurgie orthopédique et traumatologique, hôpital Roger-Salengro, CHU de Lille, place de Verdun, 59037 Lille, France.Département universitaire de chirurgie orthopédique et traumatologique, hôpital Roger-Salengro, CHU de Lilleplace de VerdunLille59037France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

The HOOS and KOOS scoring questionnaires comprise respectively 40 and 42 items; a shorter 12-item version was recently developed, but remains to be validated in a French-speaking population. We therefore conducted a prospective study: 1) to determine whether the new 12-item versions in French are equivalent to the longer HOOS and KOOS versions, and 2) to validate the French-language HOOS-12 and KOOS-12 patient-reported outcome measures in a population of primary total hip and knee arthroplasty: validity, reliability, and responsiveness.

Hypothesis

The change in language in a score already validated in its long version does not alter its properties in the short version.

Material and methods

One hundred patients (59 males, 41 females) undergoing primary total hip arthroplasty and 100 patients (43 males, 57 females) undergoing primary total knee arthroplasty were prospectively included. They filled out the original HOOS or KOOS questionnaires, their simplified versions (PS: Physical function Short form; JR: Joint Replacement) and the short HOOS-12 and KOOS-12 versions, and also the Oxford-12 score assessing the affected joint, preoperatively, then at 6–12 months.

Results

The 100% response rate confirmed ease of use. There were no redundant items. There were strong correlations between the 12-item and longer versions (>0.9). The HOOS-12 and KOOS-12 scores were reliable and valid: 1) there were no ceiling or floor effects for pre- or postoperative KOOS-12 scores, although a ceiling effect was found for HOOS-12 postoperatively (20% of patients having maximum scores of 100); 2) internal consistency was confirmed, with Cronbach alpha>0.8; 3) external consistency between Oxford-12 and HOOS-12/KOOS-12 was excellent, with Pearson correlation coefficient>0.8. Sensitivity to pre-/postoperative change was confirmed, with effect size>0.8.

Discussion

The present study confirmed the usefulness of this new 12-item form for HOOS and KOOS. Properties were identical between the French- and English-language versions, authorising everyday use of these simpler versions.

Level of evidence

IV; prospective study without control group.

Le texte complet de cet article est disponible en PDF.

Keywords : PROM, Hip, Knee, KOOS, HOOS, Total hip arthroplasty, Total knee arthroplasty


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 3

Article 102824- mai 2021 Retour au numéro
Article précédent Article précédent
  • Can the minimal clinically important difference be determined in a French-speaking population with primary hip replacement using one PROM item and the Anchor strategy?
  • Sophie Putman, Julien Dartus, Henri Migaud, Gilles Pasquier, Julien Girard, Cristian Preda, Alain Duhamel
| Article suivant Article suivant
  • Validation of the French version of the self-administered international hip outcome tool-33 questionnaire
  • Marc-Olivier Dion, Philippe-Alexandre Faure, Olivier May, Nicolas Bonin, Paul Beaulé, Sasha Carsen, Marie-Lyne Nault, Stephane Pelet, David Simonyan, Etienne L. Belzile

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.