S'abonner

Lower early revision rates after uncemented Oxford Unicompartmental Knee Arthroplasty (UKA) than cemented Oxford UKA: A meta-analysis - 27/04/21

Doi : 10.1016/j.otsr.2021.102802 
Jinhui Ma a, Yan Yan b, Weiguo Wang a, Bailiang Wang a, , Debo Yue a, Wanshou Guo a
a Department of Orthopaedic Surgery, Center for Osteonecrosis and Joint Preserving & Reconstruction, China-Japan Friendship Hospital, 2 Yinghuadong Road, Chaoyang District, Beijing 100029, China 
b Department of Orthopaedic Surgery, Peking University China–Japan Friendship School of Clinical Medicine, Beijing 100029, China 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

UKA has been proved to offer good results in treating patients with unicompartmental knee osteoarthritis (OA). However, there is still a controversy about the better fixation mode in UKA procedure between cemented and uncemented prosthesis. Therefore, this meta-analysis was conducted to compare clinical and radiological outcomes of cemented versus uncemented Oxford UKA.

Hypothesis

The study surmised that uncemented Oxford UKA was associated with shorter operation time, higher function scores, lower revision rate and less radiolucency than cemented Oxford UKA.

Methods

A meta-analysis to compare postoperative outcomes between cemented and uncemented Oxford UKA wsa conducted. The primary outcomes included Oxford knee score (OKS), revision rate, and incidence of radiolucency. The secondary outcomes included operation time, knee society score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), range of motion (ROM). PubMed, Embase, Web of Science, the Cochrane Library and China national knowledge infrastructure were searched until April, 2020 to identify studies for including. Relevant data were analyzed using RevMan v5.3.

Results

We identified nine studies involving 901 patients meeting our inclusion criteria. No significant difference of OKS was found in both groups. Compared with cemented group, uncemented Oxford UKA group was associated with lower revision rate (95% CI: 0.90 to 3.73; OR=1.83) and less radiolucent lines (95% CI: 0.79 to 9.52; OR=2.75) after following up for at least 2years. The operation time was significantly shorter by 10.12minutes (95% CI: p<0.00001) in the uncemented group when compared against the cemented group. The KSS, WOMAC, ROM were not significantly different between two groups.

Conclusions

Uncemented Oxford UKA had lower revision rate, shorter operation time and less radiolucent lines than cemented Oxford UKA did. There is still need for more long follow-up clinical trials with high evidence level to determine which method of fixation is of preferable for Oxford UKA in the future.

Level of evidence

I.

Le texte complet de cet article est disponible en PDF.

Keywords : Unicompartmental knee arthroplasty, Knee prosthesis, Cemented, Uncemented


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 3

Article 102802- mai 2021 Retour au numéro
Article précédent Article précédent
  • The ceiling effects of patient reported outcome measures for total knee arthroplasty
  • Lukas Eckhard, Selin Munir, David Wood, Simon Talbot, Roger Brighton, Bill Walter, Jonathan Baré
| Article suivant Article suivant
  • Oxford Knee Score and EQ-5d poorly predict patient's satisfaction following mechanically aligned total knee replacement: A cross-sectional study
  • Advaith Gummaraju, Cedric Maillot, Kwaku Baryeh, Loic Villet, Charles Rivière

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.