S'abonner

Novel rigidizing overtube for colonoscope stabilization and loop prevention (with video) - 12/02/21

Doi : 10.1016/j.gie.2020.07.054 
Mike Tzuhen Wei, MD 1, 2, , Joo Ha Hwang, MD, PhD 1, Rabindra R. Watson, MD 3, Walter Park, MD 1, Shai Friedland, MD 1, 2
1 Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA 
2 Department of Gastroenterology and Hepatology, Veterans Affairs Palo Alto Health Care System, Palo Alto, California, USA 
3 Interventional Endoscopy Services, California Pacific Medical Center, San Francisco, California, USA 

Reprint requests: Mike T. Wei, MD, Division of Gastroenterology and Hepatology, Stanford University Medical Center, 300 Pasteur Dr, Palo Alto, CA 94305.Division of Gastroenterology and HepatologyStanford University Medical Center300 Pasteur DrPalo AltoCA94305

Abstract

Background and Aims

Loop formation can impede endoscope advancement, destabilize the tip, and cause pain. Strategies to mitigate looping include torque-based reduction maneuvers, variable stiffness shafts, and abdominal splinting. In some cases, these strategies are insufficient, and there is need for novel instruments. Loop formation is of particular concern in colonoscopy, but it can also impact performance of other endoscopic procedures such as enteroscopy and altered-anatomy ERCP. In this case series we demonstrate the utility of a novel rigidizing overtube (Pathfinder; Neptune Medical, Burlingame, Calif, USA) in colonoscopy and other endoscopic procedures where loop management is critical.

Methods

We describe our initial experience with the Pathfinder overtube in 29 patients. The overtube is 85 cm long and can accommodate a pediatric colonoscope. In its native state, the overtube is extremely flexible. Once the overtube is advanced to the desired location, application of a vacuum to the device causes the device to become 15 times stiffer. The endoscope can then be advanced through the overtube without loop formation in the region that the overtube traverses.

Results

The overtube was used in 29 patients to assist with difficult procedures. Patients were predominantly men (n = 18; 62.1%), with a median age of 66 years (interquartile range, 57-72). One patient received an upper endoscopy (3.4%), 24 received colonoscopy (82.8%), and 4 received enteroscopy (13.8%). The overtube was used in 12 procedures for incomplete colonoscopy (41.4%), 6 for depth (20.7%), and 11 for stability (37.9%). Colonoscopy was performed in the setting of screening (n = 3), surveillance given polyp history (n = 7), referrals for polyp removal (n = 10), workup of iron deficiency anemia (n = 2), and incomplete colonoscopy (n = 1). The lower endoscopy cases had a median cecal intubation time of 5 minutes (interquartile range, 4.25-7). Enteroscopy was performed in 4 patients: In one patient the distal 60 cm of the ileum was examined with a pediatric colonoscope to exclude ileitis, in another the overtube was used to stabilize a 6-mm endoscope to traverse a tight Crohn’s ileocolonic stricture, in a third patient altered-anatomy ERCP was performed using an enteroscope through the overtube to reach a hepaticojejunostomy, and in the final patient upper enteroscopy was performed and the mid-jejunum was reached. We present 4 cases that demonstrate the use of the overtube. There were no adverse events.

Conclusions

Initial experience with a novel rigidizing overtube suggests that this tool can be useful in colonoscopy and other endoscopic procedures affected by looping.

Le texte complet de cet article est disponible en PDF.

Abbreviations : IQR, FDA


Plan


 DISCLOSURE: The following authors disclosed financial relationships: J. H. Hwang: Consultant for Olympus, Medtronic, Boston Scientific, Micro-tech, and Lumendi. R. R. Watson: Consultant for Apollo Endosurgery, Boston Scientific, and Neptune Medical; speaker for Apollo Endosurgery. W. Park: Consultant for Olympus, Abbvie, BioNTech, Interpace, and Recro Pharma. S. Friedland: Consultant for Capsovision. All other authors disclosed no financial relationships.
 If you would like to chat with an author of this article, you may contact Dr Wei at mtwei@stanford.edu.


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 93 - N° 3

P. 740-749 - mars 2021 Retour au numéro
Article précédent Article précédent
  • Automated endoscopic assessment in ulcerative colitis: the next frontier
  • Jimmy K. Limdi, Francis A. Farraye
| Article suivant Article suivant
  • Application of optical character recognition with natural language processing for large-scale quality metric data extraction in colonoscopy reports
  • Sobia Nasir Laique, Umar Hayat, Shashank Sarvepalli, Byron Vaughn, Mounir Ibrahim, John McMichael, Kanza Noor Qaiser, Carol Burke, Amit Bhatt, Colin Rhodes, Maged K. Rizk

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.