S'abonner

Serum pooling for rapid expansion of anti-SARS-CoV-2 antibody testing capacity - 31/01/21

Doi : 10.1016/j.tracli.2020.10.008 
J.W.L. Allen a, b, H. Verkerke a, b, J. Owens a, B. Saeedi a, D. Boyer a, S. Shin a, J.D. Roback a, A.S. Neish a, S.R. Stowell a, b,
a Department of Laboratory Medicine and Pathology, Center for Transfusion Medicine and Cellular Therapies, Emory University School of Medicine, 201, Dowman Dr, 30322 Atlanta, GA, United States 
b Department of Pathology, Joint Program in Transfusion Medicine, Harvard Medical School, Brigham and Women's Hospital, 630D New Research Building, 02115 Boston, MA, United States 

Corresponding author at: Department of Pathology, Joint Program in Transfusion Medicine, Harvard Medical School, Brigham and Women's Hospital, 630D New Research Building, 02115 Boston, MA, United States.Department of Pathology, Joint Program in Transfusion Medicine, Harvard Medical School, Brigham and Women's Hospital630D New Research BuildingBoston, MA02115United States

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Objectives

Examine possible pooling strategies designed to expand SARS-CoV-2 serological testing capacity.

Methods

Negative pools were assessed to determine optimal optical density (OD) cutoffs, followed by spiking weak or strong positive samples to assess initial assay performance. Samples were then randomly subjected to pool and individual testing approaches.

Results

Single positive specimens consistently converted pools of 5, 10, or 20 into positive outcomes. However, weaker IgG-positive samples failed to similarly convert pools of 50 to a positive result. In contrast, a stronger individual positive sample converted all pools tested into positive outcomes. Finally, examination of 150 samples configured into pools of 5, 10, 20 or 50 accurately predicted the presence of positive or negative specimens within each pool.

Conclusions

These results suggest that pooling strategies may allow expansion of serological testing capacity. While limitations exist, such strategies may aid in large-scale epidemiological screening or identification of optimal convalescent plasma donors.

Le texte complet de cet article est disponible en PDF.

Keywords : COVID-19, Serology, Pooling, Infectious disease


Plan


© 2020  Société française de transfusion sanguine (SFTS). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 28 - N° 1

P. 51-54 - février 2021 Retour au numéro
Article précédent Article précédent
  • Quality validation of platelets obtained from the Haemonetics and Trima Accel automated blood-collection systems
  • H.-H. Wang, L.-N. Liao, C.-L. Lin, L.-L. Yen, Y.-M. Hsiao, J.-L. Ko
| Article suivant Article suivant
  • Post-donation information and haemovigilance reporting for COVID-19 in Greece: Information supporting the absence of SARS-CoV-2 possible transmission through blood components
  • C. Politis, M. Papadaki, L. Politi, G. Kourti, C. Richardson, M. Asariotou, A. Tsakris, A. Mentis

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.