Can atrioventricular node ablation be safely performed in patients with permanent His bundle pacing? Data from a French multicentric registry - 09/01/21

Doi : 10.1016/j.acvdsp.2020.10.193 
C. Chaumont 1, , N. Auquier 2, A. Milhem 3, A. Savoure 1, A. Mirolo 1, B. Godin 1, G. Viart 1, A. Al Arnaout 3, E. Popescu 2, H. Eltchaninoff 1, F. Anselme 1
1 Department of Cardiology, Rouen University Hospital, Rouen 
2 Department of Cardiology, Groupe hospitalier du Havre, Le Havre 
3 Department of Cardiology, La Rochelle Hospital, La Rochelle, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Ventricular rate control is essential in the management of atrial fibrillation. Atrioventricular node ablation (AVNA) and ventricular pacing can be an effective option when pharmacological rate control is insufficient. However, right ventricular pacing induces ventricular desynchronisation in patients with normal QRS and increases the risk of heart failure on long-term. His bundle pacing (HBP) is a physiological alternative. There is still very limited data about the feasibility of AVNA after HBP.

Purpose

To evaluate feasibility and safety of HBP followed by AVNA in patients with non-controlled atrial arrhythmia.

Methods

We included all patients who underwent AVNA for non-controlled atrial arrhythmia after HBP implantation in 3 hospitals. No back-up ventricular lead was implanted. AVNA procedures were performed with 8 mm-tip ablation catheters.

Results

AVNA after HBP lead implantation was performed in 50 patients. AVNA was successful in 36 of 50 patients (72%). Modulation of the AV node conduction was obtained in 8 patients (16%). The mean procedure duration was 44±25min, and mean fluoroscopy duration was 5.9±7.7min. A mean number of 6.6±9.0 RF applications (315±450 s) were delivered to obtain complete/incomplete AV block. Acute HB capture (HBC) threshold increase>1V occurred in 9 patients (18%) with return to baseline value at day 1 in 6. There was no lead dislodgment. Mean HBC threshold after AVNA was 1.25±0.78V@0.5ms. AV node re-conduction was observed in 6 patients (16.7%). No ventricular lead revision was required during the follow-up period. The baseline native QRS duration was 102±21ms and the paced QRS duration was 107±18ms (Fig. 1).

Conclusion

AVNA combined with HBP for non-controlled atrial arrhythmia is feasible and does not compromise HBC but seems technically difficult with significant AV nodal re-conduction rate. The presence of a back-up ventricular lead could have changed our results and would require further evaluation.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 1

P. 85 - janvier 2021 Retour au numéro
Article précédent Article précédent
  • Cardiac resynchronisation therapy in patients with cardiac amyloidosis: A multicentre retrospective study
  • K. Fischer, N. Lellouche, T. Damy, R. Martins, N. Clementy, A. Bisson, F. Lesaffre, M. Espinosa, R. Garcia, B. Degand, G. Serzian, J. Guichard, G. Laurent, C. Guenancia
| Article suivant Article suivant
  • What can we learn from hyper-responders to cardiac resynchronisation therapy (CRT)? Characteristics and predictors of super response to CRT. An Algerian single centre experience
  • R. Benkouar, M.S. Ait Messaoudene, Y. Aoudia, A. Boudrifa, K. Bouasria, Y. Tir, O. Kassoul, H. Elnajer, L. Ouabdeslem, N. Ali Tatar, M.T. Chentir, Y. Bouhouita

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.