Résumé

Introduction

During the development of aortic valve replacement (AVR) by minimally invasive approach, the use of suturless (Perceval) and rapid deployment valves (Intuity and Intuity Elite) grew in popularity due to they are surgical time-saving.

Purpose

Our aim was to evaluated the efficacy and safety of these type of valve compared to conventional sutured valve in isolated AVR by right anterior minithoracotomy (RAMT).

Methods

Between September 2009 and March 2020, 546 patients underwent isolated AVR by RAMT. Patient data were collected prospectively. Statistical analysis was performed to compare the use of suturless and rapid deployment valve (SRDV) and conventional sutured valve (CV).

Results

Of the 546 patients, 398 underwent AVR using CV (72,9%) and 148 using a SDRV (27,1%). The aortic cross-clamping and cardiopulmonary bypass times were significantly decreased in SRDV group (66,6±27 vs 88,5±27,6min; P<0,001 and 95±39,7 vs. 119±41min; P<0,001). The rate of permanent pacemaker implantation was significantly higher in SRDV group (10,9 vs 1,05%; P<0,001). Pacemaker implantation was predominant with using Perceval valve compared to Intuity valve (12,6 vs. 3,6%). The lengths of ICU and hospital stay were significantly decreased in group CV (2,5±2,4 vs. 3,1±3,7 days; P=0,03 and 8,1±5 vs. 8.9±4.6 days; p=0,001). The mortality rate was significantly higher (4,7 vs. 1,2%; P=0,01) in group SRDV but the mean age and Euroscore II were significantly higher in SRDV group (76,1+- 6,2 vs. 68,5±9,8 years; P<0.001 and 2,1±1,9 vs. 1,6±2,1; P<0.001).

Conclusions

The use of SDRV in minimally invasive aortic valve surgery reduces the duration of myocardial ischemia, but at the cost of a significant increase in rate of permanent pacemaker implantation. Their use is also associated with a significant increase in the length of stay in intensive care unit and hospital.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 1

P. 72 - janvier 2021 Retour au numéro
Article précédent Article précédent
  • Adequate P2Y12 inhibition by clopidogrel increases adverse clinical events in patients undergoing transcatheter aortic valve replacement
  • K. Matsushita, B. Marchandot, M. Kibler, J. Heger, M. Peillex, A. Trimaille, S. Hess, L. Grunebaum, M. Ohana, A. Reydel Dedieu, L. Jesel, P. Ohlmann, O. Morel
| Article suivant Article suivant
  • Severe aortic stenosis and chronic kidney disease: Outcomes and impact of aortic valve replacement
  • Y. Bohbot, A. Candellier, D. Rusinaru, A. Altes, A. Pasquet, S. Marechaux, J.L. Vanoverschelde, C. Tribouilloy

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.