S'abonner

The impact of left atrium size on selection of the pulmonary vein isolation method for atrial fibrillation: Cryoballoon or radiofrequency catheter ablation - 18/12/20

Doi : 10.1016/j.ahj.2020.10.061 
Takashi Ikenouchi, MD a, , Osamu Inaba, MD, PhD a, Tomomasa Takamiya, MD, PhD a, Yukihiro Inamura, MD, PhD a, Akira Sato, MD a, Yutaka Matsumura, MD, PhD a, Hiroyuki Sato, PhD b, Akihiro Hirakawa, PhD b, Yoshihide Takahashi, MD, PhD c, Masahiko Goya, MD, PhD c, Tetsuo Sasano, MD, PhD c, Junichi Nitta, MD, PhD d
a Department of Cardiology, Japanese Red Cross Saitama Hospital, 1-5 Shintoshin, Chuo-ku, Saitama City, Saitama, Japan 
b Division of Biostatistics and Data Science, Clinical Research Center, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, Japan 
c Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, Japan 
d Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahicho, Fuchu-shi, Tokyo, Japan 

Reprint requests: Takashi Ikenouchi, MD, Department of Cardiology, Japanese Red Cross Saitama Hospital, 1-5 Shintoshin, Chuo-ku, Saitama City, Saitama, 330-8553, Japan.Department of Cardiology, Japanese Red Cross Saitama Hospital1-5 Shintoshin, Chuo-ku, Saitama CitySaitama330-8553Japan

Résumé

Background

Pulmonary vein isolation (PVI) is the cornerstone of ablation strategies for atrial fibrillation (AF), and noninferiority of cryoballoon (CB) over radiofrequency (RF) ablation has been previously reported. One of the risk factors of recurrence is left atrium (LA) enlargement. This study aimed to analyze the impact of LA enlargement on the selection of CB or RF ablation for AF patients.

Methods

A total of 2,224 AF patients (64.4 ± 10.7 years, 65.5% male) who underwent PVI were analyzed retrospectively. Left atrial diameter (LAD) and volume (LAV) were measured using echocardiography before the procedures. LA enlargement was defined as LAD ≥40 mm and LAV index (LAVI) ≥35 mL/m2. Patients undergoing CB and RF ablation were propensity score matched, and 376 matched pairs were evaluated.

Results

Cox proportional hazard analysis revealed that LAD (95% CI, 1.01-1.05), LAV (95% CI, 1.01-1.02), and LAVI (95% CI, 1.01-1.03) were independent predictors of recurrence. CB showed equivalent clinical outcomes to those of RF with shorter procedure time required for patients without LA enlargement. CB was inferior to RF in patients with LA enlargement (LAD, 74.5% vs 84.6%, P = .028; LAVI, 74.7% vs 83.4%, P = .015), and large LAVI was associated with a higher prevalence of non-PV foci (35% vs 29%, P = .008).

Conclusions

CB ablation may be recommended for patients without enlarged LA based on the short procedure time and efficacy, whereas RF would be more appropriate in large LAs. LAVI may be a valuable reference to predict PVI outcomes and in selecting the ablation method.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 231

P. 82-92 - janvier 2021 Retour au numéro
Article précédent Article précédent
  • Long-term outcomes of arrhythmia and distinct electrophysiological features in congenitally corrected transposition of the great arteries in an Asian cohort
  • Wei-Chieh Tseng, Chi-Nan Huang, Shuenn-Nan Chiu, Chun-Wei Lu, Jou-Kou Wang, Ming-Tai Lin, Chun-An Chen, Mei-Hwan Wu
| Article suivant Article suivant
  • Helicobacter pylori screening in clinical routine during hospitalization for acute myocardial infarction
  • Jonatan Wärme, Martin Sundqvist, Katarina Mars, Layth Aladellie, Sven-Christian Pawelzik, David Erlinge, Tomas Jernberg, Stefan James, Robin Hofmann, Magnus Bäck

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.