S'abonner

Haemodynamic monitoring and management in COVID-19 intensive care patients: an International survey - 09/10/20

Doi : 10.1016/j.accpm.2020.08.001 
Frédéric Michard a, , Manu LNG Malbrain b, Greg S Martin c, Thierry Fumeaux d, Suzana Lobo e, Filipe Gonzalez f, Vitor Pinho-Oliveira g, Jean-Michel Constantin h
a MiCo, Denens, Switzerland 
b Intensive Care Unit, University Hospital Brussel, Jette, Belgium & Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium 
c Emory University and Grady Memorial Hospital, Atlanta, USA 
d Intensive Care Unit, Nyon Hospital, Nyon, Switzerland 
e Intensive Care Division, Hospital de Base - FAMERP, Sao Jose do Rio Preto, SP, Brazil 
f Intensive Care Department, Hospital Garcia de Orta, Almada, Portugal 
g Department of Anesthesia, Hospital CUF Viseu, Viseu, Portugal 
h Department of Anesthesia & Critical Care, La Pitié Salpetriere Hospital, University Paris-Sorbonne, Paris, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

To survey haemodynamic monitoring and management practices in intensive care patients with the coronavirus disease 2019 (COVID-19).

Methods

A questionnaire was shared on social networks or via email by the authors and by Anaesthesia and/or Critical Care societies from France, Switzerland, Belgium, Brazil, and Portugal. Intensivists and anaesthetists involved in COVID-19 ICU care were invited to answer 14 questions about haemodynamic monitoring and management.

Results

Globally, 1000 questionnaires were available for analysis. Responses came mainly from Europe (n = 460) and America (n = 434). According to a majority of respondents, COVID-19 ICU patients frequently or very frequently received continuous vasopressor support (56%) and had an echocardiography performed (54%). Echocardiography revealed a normal cardiac function, a hyperdynamic state (43%), hypovolaemia (22%), a left ventricular dysfunction (21%) and a right ventricular dilation (20%). Fluid responsiveness was frequently assessed (84%), mainly using echo (62%), and cardiac output was measured in 69%, mostly with echo as well (53%). Venous oxygen saturation was frequently measured (79%), mostly from a CVC blood sample (94%). Tissue perfusion was assessed biologically (93%) and clinically (63%). Pulmonary oedema was detected and quantified mainly using echo (67%) and chest X-ray (61%).

Conclusion

Our survey confirms that vasopressor support is not uncommon in COVID-19 ICU patients and suggests that different haemodynamic phenotypes may be observed. Ultrasounds were used by many respondents, to assess cardiac function but also to predict fluid responsiveness and quantify pulmonary oedema. Although we observed regional differences, current international guidelines were followed by most respondents.

Le texte complet de cet article est disponible en PDF.

Keywords : COVID-19, Haemodynamics, Echocardiography, Shock, Acute circulatory failure


Plan


© 2020  Société française d'anesthésie et de réanimation (Sfar). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 39 - N° 5

P. 563-569 - octobre 2020 Retour au numéro
Article précédent Article précédent
  • SARS-CoV-2 in Spanish Intensive Care Units: Early experience with 15-day survival in Vitoria
  • Helena Barrasa, Jordi Rello, Sofia Tejada, Alejandro Martín, Goiatz Balziskueta, Cristina Vinuesa, Borja Fernández-Miret, Ana Villagra, Ana Vallejo, Ana San Sebastián, Sara Cabañes, Sebastián Iribarren, Fernando Fonseca, Javier Maynar, Alava COVID-19 Study Investigators
| Article suivant Article suivant
  • Ultrasound findings in patients with COVID-19 pneumonia in early and late stages: Two case-reports
  • Laurent Zieleskiewicz, Gary Duclos, Ophélie Dransart-Rayé, Nicolas Nowobilski, Belaid Bouhemad

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.