S'abonner

The role of ?1AMP-activated protein kinase (?1AMPK) in vascular dysfunctions induced by sepsis - 25/09/20

Doi : 10.1016/j.acvdsp.2020.03.011 
J. De Poortere 1, , M. Angé 1, L. Bertrand 1, S. Horman 1, C. Beauloye 1, 2, D. Castanares-Zapatero 1, 2, 3
1 Université Catholique de Louvain 
2 Division de cardiologie 
3 Division de soins intensifs, Cliniques universitaires Saint-Luc, Bruxelles, Belgique 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Sepsis is a pathological circumstance whose outcome is associated with organ dysfunction and death. Vascular hyperpermeability and haemostasis impairment, both play a key role in the onset of organ failure. Our previous work highlighted the protective role of α1AMPK against sepsis-induced hyperpermeability. However, the impact of α1AMPK on haemostasis has never been investigated in this condition.

Objectives

This study aims to characterize the interaction of α1AMPK with hemostasis in sepsis.

Methods

C57BL6J mice and α1AMPK wild-type (WT) and knock-out (KO) mice were challenged with intraperitoneal injection of lipopolysaccharide (LPS) from Escherichia coli O55B5 (10mg.kg-1) during 6hours. Plasmatic markers of coagulation, platelet and NETosis activation were measured by ELISA and membrane markers of platelet activation were analysed by flow cytometry. The dsDNA analysis of NETosis was performed by fluorometry. Ex vivo platelets activation was assessed by flow cytometry on platelets α1AMPK WT and KO, incubated in a medium with 5μg/mL of LPS.

Results

In C57BL6J mice, haemostasis was activated 6hours after LPS administration, as reflected by the increase in fibrinogen, plasminogen activator inhibitor and tissue plasminogen activator. In addition, platelets isolated from LPS-treated mice were activated as demonstrated by the increased exposure of CD62P and αIIbβIII on platelet surface and soluble CD62P detection in plasma. Finally, we measured a significant increase in myeloperoxidase, neutrophil elastase and plasmatic dsDNA, all markers of NETosis. Same parameters were measured in α1AMPK WT and KO mice. We brought out an increase of fibrinolysis impairment and heightened a trend of NETosis in α1AMPK undergoing sepsis. Furthermore, platelets of α1AMPK KO mice exhibited a more important activation ex vivo, in response to LPS.

Conclusion

These results suggest that α1AMPK is involved in the regulation of hemostasis disturbances following sepsis.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 12 - N° 2-4

P. 203 - octobre 2020 Retour au numéro
Article précédent Article précédent
  • Assessing the impact of switching to the Tobacco Heating System on cardiovascular disease: Translating basic science into clinical benefit
  • C. Pater, G. Baker, G. De La Bourdonnaye, A. Elamin, C. Goujon, C. Haziza, A. Heremans, J. Hoeng, N. Ivanov, F. Luedicke, S. Maeder, B. Phillips, P. Picavet, S. Pouly, C. Poussin, P. Pratte, C.T. Tran, P. Vanschveeuwiijck, M. Peitsch
| Article suivant Article suivant
  • From the antiplatelet drug ticagrelor to antibiotics: A study of structure-activity relationships
  • N. Jacques, E. Goffin, L. Musumeci, B. Pirotte, C. Oury, P. Lancellotti

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.