S'abonner

Incidence of Infection and Antimicrobial Consumption in Ventricular Assist Device (VAD) Recipients at the Prince Charles Hospital (TPCH): A Retrospective Analysis - 21/08/20

Doi : 10.1016/j.hlc.2020.02.002 
Stephen Belz, MClinPharm, MPS a, , Stephanie Fisquet, BPharm a, Abhilasha Ahuja, MD, FCICM a, Karen Hay, PhD b, Jayshree Lavana, MD, FCICM a
a Intensive Care Unit, The Prince Charles Hospital, Brisbane, Qld, Australia 
b QIMR Berghofer Medical Research Institute, Royal Brisbane Hospital, Brisbane, Qld, Australia 

Corresponding author at:

Abstract

Background

Ventricular assist devices (VADs) are frequently used as a bridge to heart transplant; however, infections are a common cause of increased morbidity and mortality. The optimal prophylactic antimicrobial regimen has not been effectively evaluated in literature.

Methods

Forty-three (43) patients received a VAD over the 5-year study period (2012–2017) at The Prince Charles Hospital (TPCH), Brisbane Australia. Of these, 41 patients were followed from implantation until transplantation or death. Antimicrobial prophylactic regimens and individual episodes of infection were recorded. The infection profiles, including types and incidence were compared to published literature using definitions from the International Society for Heart and Lung Transplantation (ISHLT) guidelines for consistency.

Results

Median duration of VAD insertion was 79 days (IQR: 36–167). Patients received aztreonam, fluconazole and vancomycin (median duration 8 days). Twenty-two (22) (53.6%) patients experienced a VAD-specific and/or a VAD-related infective episode. Incidence of infection in the study cohort was 0.60 infections per 100 patient days. Thirteen (13) patients (31.7%) experienced 16 VAD-specific infections which were all driveline infections. Thirteen (13) patients (31.7%) experienced 14 VAD-related infections. The predominant VAD-related infection type was bacteraemia (36%). Predominant bacterial profiles of VAD-specific as well as VAD related infections were gram positive. Only three episodes had a gram negative as a causative pathogen which occurred much later post VAD insertion. Median time till VAD-specific or VAD-related infection was 46 and 15 days respectively. Obesity was significantly associated with increased risk of infection (HR: 3.2; 95% CI: 1.3–7.4).

Conclusions

Infection is a common complication of VAD implantation. In our study population gram positive bacteria were the predominant causative pathogen. Based on the micro-organism profile there may be scope for a narrowing of the antibiotic regimen. A larger, multicentre study would be able to accurately guide a change. The information gathered in our study offers a strong foundation for such a multicentre study.

Le texte complet de cet article est disponible en PDF.

Keywords : Ventricular assist device, Infection, Antimicrobial


Plan


© 2020  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 29 - N° 8

P. 1234-1240 - août 2020 Retour au numéro
Article précédent Article précédent
  • Outcomes of Asian-Americans Implanted With Left Ventricular Assist Devices: An Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Analysis
  • Iosif Taleb, James Wever-Pinzon, Wenyan Wang, Antigone Koliopoulou, Elizabeth Dranow, Tao Yu, Lixue Yin, Stephen H. McKellar, Josef Stehlik, James C. Fang, Omar Wever-Pinzon, Craig H. Selzman, Stavros G. Drakos
| Article suivant Article suivant
  • SSRI/SNRI Therapy is Associated With a Higher Risk of Gastrointestinal Bleeding in LVAD Patients
  • George Mawardi, Tim M. Markman, Rahatullah Muslem, Minoosh Sobhanian, Maureen Converse, Holly B. Meadows, Walter E. Uber, Stuart D. Russell, Rosanne Rouf, Bhavadharini Ramu, Daniel P. Judge, Ryan J. Tedford, Brian A. Houston

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.