S'abonner

Évaluation de la fiabilité d’un nouveau dispositif de mesure de la contraction relative du muscle transverse abdominal en comparaison aux ultrasons et à la palpation dans une population asymptomatique – étude exploratoire - 20/08/20

Assessment of the reliability of a novel device for measuring relative transverse abdominal muscle contraction compared to ultrasound and palpation in an asymptomatic population – An exploratory study

Doi : 10.1016/j.kine.2020.04.012 
Caroline Pautard a, , Clément Jouanneau a, Anne-Gaëlle Servel a, Servane Cosqueric b, Manon Bessette c, Yann Le Faou c, Pauline Hardouin c
a Société Blueback, 1137A, avenue des Champs-Blancs, 35510 Cesson-Sévigné, France 
b 55, rue de l’avenir, 35310 Chavagne, France 
c IFPEK, 12, rue Jean-Louis Bertrand, 35000 Rennes, France 

Auteur correspondant : Société Blueback, 1137A, avenue des Champs-Blancs, 35510 Cesson-Sévigné, France.Société Blueback1137A, avenue des Champs-BlancsCesson-Sévigné35510France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 14
Vidéos 0
Autres 0

Résumé

La position et le fonctionnement du muscle transverse de l’abdomen font que le patient a souvent de la peine à ressentir sa contraction. Ciblé dans de nombreux traitements, il participe active-ment à la stabilisation du rachis, mais également à de nombreux processus biologiques (digestion, respiration). L’évaluation de son rôle est souvent remise en cause en raison du manque d’outils fiables dédiés à la mesure de son activité contractile. L’objectif de cette étude exploratoire était d’évaluer la fiabilité d’un nouveau dispositif de biofeedback par mesure électro-myographique (Blueback® Physio) en comparaison à deux méthodes standards, la palpation manuelle et l’imagerie par échographie. Quatre sujets ont été inclus dans le bras no 1. Ils ont suivi un protocole utilisant le Blueback® Physio et, en comparaison, ont eu une palpation effectuée par un kinésithérapeute. Neuf sujets, inclus dans le bras no 2, ont suivi un protocole utilisant le Blueback® Physio, et, en comparaison, ont eu un suivi échographique. La corrélation moyenne entre la réponse du Blueback® Physio et la réponse de l’échographie était de 97 %. Dans 84 % des cas, les contractions du muscle transverse de l’abdomen ont été détectées par le biofeedback EMG légèrement en avance par rapport à l’échographie (écart moyen de 380ms entre les deux systèmes, p<0,001).

Le texte complet de cet article est disponible en PDF.

Summary

The position and function of the transverse muscle of the abdomen often makes it difficult for the patient to feel its contraction. Targeted in many treatments, it participates actively in the stabilization of the spine, but also in many biological processes (digestion, breathing). The evaluation of its role is often questioned due to the lack of reliable tools dedicated to the measurement of its contractile activity. The objective of this exploratory study was to evaluate the reliability of a new biofeedback device by electro-myographic measurement (Blueback® Physio) compared to two standard methods, manual palpation and ultrasound imaging. Four subjects were included in arm no 1. They followed a protocol using Blueback® Physio and, in comparison, were palpated by a physiotherapist. Nine subjects, included in arm no 2, followed a protocol using Blueback® Physio, and, in comparison, had an ultrasound follow-up. The mean correlation between Blueback® Physio response and ultrasound response was 97 %. In 84 % of cases, contractions of the transverse muscle of the abdomen were detected by the EMG biofeedback slightly ahead of the ultrasound (mean difference of 380ms between the two systems, P<0.001).

Le texte complet de cet article est disponible en PDF.

Mots clés : Biofeedback, Dispositif de mesure, Échographie, Muscle transverse abdominal

Keywords : Biofeedback, Monitoring Device, Ultrasound, Transverse abdominal muscle


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 224-225

P. 70-78 - août 2020 Retour au numéro
Article précédent Article précédent
  • Test de vitesse de marche de 4 mètres (TM-4)
| Article suivant Article suivant
  • Le dossier kinésithérapique et la justice
  • Marc Diard

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.