S'abonner

The ideal insertion angle after immediate loading in Jeil, Storm, and Thunder miniscrews: A 3D-FEM study - 20/08/20

Doi : 10.1016/j.ortho.2020.03.003 
Mauro Cozzani 1, Ludovica Nucci 2, Daniela Lupini 3, Hedieh Dolatshahizand 4, Delaram Fazeli 4, Esmaeil Barzkar 6, Ehsan Naeini 5, Abdolreza Jamilian 4,
1 Istituto Giuseppe Cozzani, La Spezia, Italy 
2 Dental School, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy 
3 Scuola di Specializzazione in Ortognatodonzia Un di Trieste and Istituto Giuseppe Cozzani, La Spezia, Italy 
4 Department of orthodontics, Dental School, Cranio Maxillofacial Research Center, Tehran medical sciences, Islamic Azad University, Tehran, Iran 
5 Department of oral and maxillofacial Surgery, Faculty of dentistry, Cranio Maxillofacial Research Center, Tehran medical sciences, Islamic Azad University, Tehran, Iran 
6 Mechanical engineering, Sharif university of technology, Tehran, Iran 

Abdolreza Jamilian, No 14, Pesiyan St., Vali Asr St., 1986944768 Tehran, Iran.No 14, Pesiyan St., Vali Asr St.Tehran1986944768Iran

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 4
Vidéos 0
Autres 0

Summary

Objective

The miniscrew is effectively used to provide additional anchorage for orthodontic purposes. The aim of this study was to identify an optimal insertion angle for Jeil, Storm, and Thunder miniscrews on stress distribution at the bone miniscrew interface.

Materials and methods

To perform 3-dimensional finite element model analysis, a 3-dimensional model with a bone block was constructed with type D2 of bone quality, and with miniscrews of Storm, Thunder, Jeil, with the diameter of 2, 1.5. 1.6mm and length 15.9, 12.4, 14.4mm respectively. The miniscrews were inserted at 15° 30°, 45°, 60°, 75° and 90° to the bone surface. A simulated horizontal orthodontic force of 200 gram was applied to the centre of the miniscrews head in all models, and stress distribution and its magnitude were evaluated with a 3-dimensional finite element analysis program.

Results

In the cancellous bone, minimum stress was found at placement angles of 90° for Jeil and Storm, which was 0.37 and 0.39MPa respectively, and 15° for Thunder, which was 0.85MPa. The maximum von Mises stresses in the cancellous bone for Jeil was at 60°, which was 0.92MPa, and for Thunder at 90°, which was 1.3MPa.

Conclusion

Each miniscrew has an ideal insertion angle, optimal insertion positions were found within 90° for Jeil and for Storm but 15° for Thunder. Clinical significance 3-dimensional finite element analysis confirmed that each miniscrew has an ideal insertion angle according to its characteristics.

Le texte complet de cet article est disponible en PDF.

Keywords : Insertion angle, Bone anchorage, TADS, Miniscrew, Mini implant


Plan


© 2020  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 18 - N° 3

P. 503-508 - septembre 2020 Retour au numéro
Article précédent Article précédent
  • Root changes in buccal versus palatal maxillary impacted canines of adults: A longitudinal and retrospective 3-dimensional study before and after orthodontic traction
  • Yalil Augusto Rodríguez-Cárdenas, Luis Ernesto Arriola-Guillén, Gustavo Armando Ruíz-Mora, Aron Aliaga-Del Castillo, Mariana Boessio-Vizzotto, Heraldo Luis Dias-Da Silveira
| Article suivant Article suivant
  • Comparation of three methods for measuring the Edge Bevel Radius of rectangular orthodontic wires: An in-vitro study
  • Ricardo Nunes, José Guilherme Neves, Milton Santamaria-Jr, Rafael Yagüe Ballester, Ana Rosa Costa, Silvia Amélia Scudeler Vedovello, Mário Vedovello Filho

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.