Disinfecting noncritical medical equipment—Effectiveness of hydrogen peroxide dry mist as an adjunctive method - 25/07/20

Doi : 10.1016/j.ajic.2020.05.016 
Enrica Amodio a, Stefan P. Kuster, MD a, Christian Garzoni, MD b, Annelies S. Zinkernagel, MD a, Hugo Sax, MD a, #, Aline Wolfensberger, MD a, #,
a Division of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland 
b Division of Internal Medicine and Infectious Diseases, Clinica Moncucco, Lugano, Switzerland 

Address correspondence to Aline Wolfensberger, MD, Division of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, CH-8091 Zurich, Switzerland.Division of Infectious Diseases and Hospital EpidemiologyUniversity Hospital ZurichUniversity of ZurichRämistrasse 100ZurichCH-8091Switzerland

Highlights

Manual disinfection of medical devices is prone to failure.
Dry mist hydrogen peroxide (HPDM) is a nonmanual automatized disinfection technique.
We evaluated the effectiveness of HPDM on ‘ready to use’ noncritical equipment.
HPDM substantially reduced bacterial burden on noncritical medical devices.

Le texte complet de cet article est disponible en PDF.

Résumé

Background

Manual disinfection of medical devices is prone to failure. Disinfection by aerosolized hydrogen peroxide might be a promising adjunctive method. We aimed to assess effectiveness of dry mist of hydrogen peroxide (HPDM) on noncritical medical equipment.

Methods

One cycle of HPDM was applied on a convenience sample of 16 different types of "ready to use" noncritical medical devices in a closed, but nonsealed room. Of every object, 2 adjacent areas with assumed similar bacterial burden were swabbed before and after HPDM deployment, respectively. After culturing, colony forming units (CFU) were counted, and bacterial burden per cm2 calculated.

Results

Of 160 objects included in the study, 36 (23%) showed a CFU-count of zero both before and after HPDM use. A decrease from a median of 0.14 CFU/cm2 (range: 0.00-125.00/cm2) to a median of 0.00 CFU/cm2 (range: 0.00-4.00/cm2) (P < .001) was observed. The bacterial burden was reduced by more than 90% in 45% (95% CI: 37-53) of objects. No pathogenic bacteria were identified.

Discussion

HPDM reduced bacterial burden on noncritical medical items. Since cleanliness of the included "ready to use" objects was high and no pathogens were found before nebulization, the HPDM device did not increase patient safety in this setting.

Conclusion

HPDM nebulization can be a useful nonmanual adjunctive disinfection method in high-risk settings.

Le texte complet de cet article est disponible en PDF.

Key Words : Hydrogen peroxide nebulizer, Disinfection, Infection prevention, Infection control, Equipment contamination, Environmental contamination


Plan


 Conflicts of interest: Christian Garzoni served as external scientific advisor to 99Technologies on Healthcare Acquired Infections from 2013 to 2017. The other authors declare no conflict of interest.
 Funding: The HPDM device (HyperDRYMist, Modulator Micro Nebulizer 99mb by 99Technologies), disinfection solution, and financial support for laboratory material was provided by 99T for the duration of the study. The funding source was not involved in study design, collection and interpretation of the data, and manuscript preparation and submission. AW is supported by the academic career program “Filling the gap” of the Medical Faculty of the University of Zurich.
 Ethics approval and consent to participate: Not applicable.
 Availability of data and materials: All data generated or analysed during this study are included in this published article and its supplementary information files.
 Authors’ contributions: AW, EA, CG, AZ and HS designed the study. EA acquired the data. AW, EA and SPK performed statistical analyses. AW, EA, SPK, and HS analyzed and interpreted the data. EA and AW drafted the manuscript, and SPK, CG, AZ, and HS provided critical review of the manuscript for important intellectual content. All authors agree with the content and conclusions of this manuscript.


© 2020  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48 - N° 8

P. 897-902 - août 2020 Retour au numéro
Article précédent Article précédent
  • Absence of nosocomial transmission of coronavirus disease 2019 (COVID-19) due to SARS-CoV-2 in the prepandemic phase in Hong Kong
  • Vincent C.C. Cheng, Shuk-Ching Wong, Vivien W.M. Chuang, Simon Y.C. So, Jonathan H.K. Chen, Siddharth Sridhar, Kelvin K.W. To, Jasper F.W. Chan, Ivan F.N. Hung, Pak-Leung Ho, Kwok-Yung Yuen
| Article suivant Article suivant
  • Maximizing efficiency in a high occupancy setting to utilize ultraviolet disinfection for isolation rooms
  • Joshua K. Schaffzin, Adam W. Wilhite, Zhaoyan Li, David Finney, Andrea L. Ankrum, Ronald Moore

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.