S'abonner

Long-term Fate of Dilated Ascending Aorta after Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Disease - 24/07/20

Doi : 10.1016/j.amjcard.2020.05.026 
Min-Seok Kim, MD, PhD, MSc, Jung Hwan Kim, MD, Seung Hyun Lee, MD, PhD, Sak Lee, MD, PhD, Young-Nam Youn, MD, PhD, Kyung-Jong Yoo, MD, PhD, Hyun-Chel Joo, MD
 Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea 

Corresponding author: Tel: 82-2-2228-8489; fax: 82-2-313-2992.

Résumé

We compared the long-term outcomes and difference in dilatation rates of the ascending aorta after aortic valve (AV) replacement (AVR) between bicuspid and tricuspid AV patients, and evaluated risk factors associated with ascending aorta dilatation and aortic events during the follow-up. Of 1,127 patients who underwent AVR from 1995 to 2015, 259 patients with a dilated ascending aorta (≥40 mm in diameter) were included. The patients were divided into those with bicuspid (group bicuspid aortic valve [BAV], n = 105) and with tricuspid (group tricuspid aortic valve [TAV], n = 154) AV, and a propensity score-matched analysis was performed to match 98 patients in each group. The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. Risk factors for ascending aorta dilatation, mortality, and aortic events were identified. Follow-up was completed in 100% of patients with a median follow-up duration of 106.1 [68.8, 163.0] months. The early clinical outcomes and dilation rate of the ascending aorta were similar between the groups. Overall survivals up to 15 years postoperatively were similar between groups BAV and TAV (p = 0.223). Aortic events occurred in 6 patients (groups BAV vs TAV, 2 vs 4;p = 0.678). Preoperative ascending aorta diameter showed a linear relationship with the dilatation rate of ascending aorta (p <0.001) and was related to progressive aortic dilatation and aortic events (odds ratio: 1.25, p <0.001 and hazard ratio = 1.56, p <0.001, respectively). In conclusion, the long-term outcomes and ascending aorta dilatation rate were similar between the BAV and TAV patients up to 15 years after AVR. Bicuspid AV was not a risk factor of mortality or aortic events.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 129

P. 53-59 - août 2020 Retour au numéro
Article précédent Article précédent
  • Cardiac Function and Sudden Cardiac Death in Heart Failure With Preserved Ejection Fraction (from the TOPCAT Trial)
  • Rajat Kalra, Kartik Gupta, Ryan Sheets, Sudeep Aryal, Ali Ebrahimi, Indranee Rajapreyar, Marc G. Cribbs, Oscar Julian Booker, Sumanth D. Prabhu, Navkaranbir S. Bajaj
| Article suivant Article suivant
  • Comparison of Outcomes of Transcatheter Aortic Valve Implantation in Patients ?85 Years Versus Those <85 Years
  • Martino Pepe, Nicola Corcione, Giuseppe Biondi-Zoccai, Alberto Morello, Sergio Berti, Francesco Bedogni, Alessandro Iadanza, Fabrizio Tomai, Gennaro Sardella, Enrico Romagnoli, Paolo Ferraro, Sirio Conte, Palma Luisa Nestola, Marcello De Giosa, Michele Cimmino, Giacomo Frati, Arturo Giordano

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.