Nocturnal hypoglycaemias in type 1 diabetic patients: what can we learn with continuous glucose monitoring? - 08/04/08

Doi : 10.1016/j.diabet.2007.03.007 

L. Guillod,

S. Comte-Perret,

D. Monbaron,

R.C. Gaillard,

J. Ruiz

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

But

Les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle qui permet de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes.

Méthode

Quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après.

Résultats

La prévalence des hypoglycémies nocturnes était de 67 % (32 % non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37 % (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22–24 h) et de 43 % lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3,95, P < 0,001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémie nocturne ont diminué de 60 à 14 % (P < 0,001).

Conclusions

Les hypoglycémies nocturnes ont une prévalence élevée et ne sont souvent pas détectées par les autocontrôles. La détection d'une hypoglycémie au coucher a une sensibilité équivalente à celle de 3 h pour prédire une hypoglycémie nocturne. Par conséquent, un autocontrôle au coucher, moins contraignant qu'à 3H, peut donc être une stratégie conseillée. Le phénomène de Somogyi n'a pas été observé. Le CGMS est utile pour réduire les hypoglycémies nocturnes suspectées chez 75 % des patients.

Abstract

Aim

In type 1 diabetic patients (T1DM), nocturnal hypoglycaemias (NH) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in T1DM, the best SMBG time to predict NH, the relationship between morning hyperglycaemia and NH (Somogyi phenomenon) and the utility of CGMS to reduce NH.

Methods

Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluation, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6–9 months.

Results

The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22–24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure ≤ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6–9 months, suspicions of NH decreased from 60 to 14% (P < 0.001).

Conclusion

NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.


Mots clés : Diabète de type 1 , Hypoglycémie nocturne , Contrôle de la glycémie en continu , Autocontrôle de la glycémie capillaire

Keywords: Continuous glucose monitoring system , Nocturnal hypoglycaemia , Self-monitoring of blood glucose , Type 1 diabetes mellitus


Plan



© 2007 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 33 - N° 5

P. 360-365 - novembre 2007 Retour au numéro
Article précédent Article précédent
  • Relationship between gamma-glutamyltransferase and fat mass in a general population of 8–17 years old children. The FLVS II study
  • J. Botton, B. Heude, P. Andre, J.L. Bresson, P. Ducimetiere, M.A. Charles
| Article suivant Article suivant
  • Dietary iron intake and serum ferritin in relation to 7.5 years structure and function of large arteries in the SUVIMAX cohort
  • A.C. Vergnaud, S. Bertrais, M. Zureik, P. Galan, J. Blacher, S. Hercberg, S. Czernichow

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.