S'abonner

Reduction of scapulohumeral subluxation with posterior augmented glenoid implants in anatomic total shoulder arthroplasty: Short-term 3D comparison between pre- and post-operative CT - 08/06/20

Doi : 10.1016/j.otsr.2020.03.007 
Alexandre Terrier a, , Patrick Goetti b, Fabio Becce c, Alain Farron b
a Laboratory of Biomechanical Orthopedics, École Polytechnique Fédérale de Lausanne, Station 9, 1015 Lausanne, Switzerland 
b Service of Orthopaedics and Traumatology, Lausanne University Hospital and University of Lausanne, 4, avenue Pierre-Decker, 1005 Lausanne, Switzerland 
c Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, 46, rue du Bugnon, 1011 Lausanne, Switzerland 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Failure rates in anatomic total shoulder arthroplasty (aTSA) are higher in case of asymmetric glenoid bone loss secondary to posterior wear, and in persistent static posterior subluxation of the humeral head (PSH).

Hypothesis

This study aimed to test the hypothesis that the combined use of posterior augmented glenoid (PAG) implants with three-dimensional (3D) surgical planning and patient-specific instrumentation (PSI) guides helps reduce short-term PSH after aTSA in patients with type B2-B3 glenoids.

Patients and methods

We included nine consecutive patients with primary glenohumeral osteoarthritis and type B2 or B3 glenoids, who underwent aTSA with cemented keeled PAG implants (posterior augments of 15, 25, or 35 degrees). All patients underwent preoperative shoulder computed tomography (CT) scans, with 3D surgical planning coupled to PSI at the time of surgery. Postoperative shoulder CT scans were performed at an average of 14 weeks (range, 10-21 weeks). Scapulohumeral subluxation and glenoid version and inclination were measured in 3D, on both pre- and post-operative CT scans, using the same reliable quantitative method.

Results

There was a significant decrease in scapulohumeral subluxation from 49±12% preoperatively to 22±17% postoperatively (p=0.0039), with a large effect size (Cohen's d=1.89). Preoperative glenoid version was corrected from −17.3±9.4 degrees to −5.2±7.5 degrees postoperatively. The absolute difference between the postoperative and surgically planned version and inclination was 5.4±3.6 degrees and 3.3±2.0 degrees, respectively.

Discussion

The combined use of PAG implants with 3D preoperative planning and PSI results in a significant decrease in short-term PSH and glenoid version in patients with asymmetric posterior glenoid wear. We suggest that such implants should not be limited to posterior augmentation, because glenoid deficiency can also be observed in other glenoid sectors.

Level of evidence

IV, Basic science study.

Le texte complet de cet article est disponible en PDF.

Keywords : Anatomic total shoulder arthroplasty, Posterior augmented glenoid implant, Scapulohumeral subluxation, Glenoid version, Patient-specific instrumentation


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 4

P. 681-686 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Immobilization in external rotation versus internal rotation after shoulder dislocation: A meta-analysis of randomized controlled trials
  • Bingbing Zhang, Yongsheng Sun, Long Liang, Xing Yu, Liguo Zhu, Si Chen, Yifei Wei, Guannan Wen
| Article suivant Article suivant
  • Recovery pattern after arthroscopic treatment for calcific tendinitis of the shoulder
  • Chul-Hyun Cho, Ki-Cheor Bae, Beom-Soo Kim, Hyung-Joo Kim, Du-Han Kim

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.