S'abonner

Eliminating projection error of measuring Pauwels’ angle in the femur neck fractures by CT plane manipulation - 08/06/20

Doi : 10.1016/j.otsr.2019.09.029 
Gyu Min Kong a, Jae-Man Kwak b, Gu-Hee Jung c, d,
a Department of Orthopaedic surgery, Inje university, Busan Paik hospital, 75, Bokji-ro, Busanjin-Gu, Busan, Republic of Korea 
b Department of Orthopedics, Biomechanics Laboratory, Mayo Clinic, Rochester, MN, USA 
c Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital, 11, Samjeongja-ro, Seongsan-gu, Changwon-si 51472, Republic of Korea 
d Medical ICT Convergence research center, institute of Health Sciences, college of Medicine, Gyeongsang National University, 816 Beongil 15, Jinju-si 52727, Republic of Korea 

Corresponding author at: Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital, 11, Samjeongja-ro, Seongsan-gu, Changwon-si 51472, Republic of Korea.Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital11, Samjeongja-ro, Seongsan-guChangwon-si 51472Republic of Korea

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Objectives

The aim for the present study was to determine whether projection error of measuring Pauwels’ angle in young femur neck fracture could be eliminated by CT plane manipulation.

Methods

Clinical data of displaced femur neck fractures in young adults aged 20 to 64years old (13 females and 17 males) were retrospectively analyzed. Their average age was 47.9years (range: 22–64years; SD: 11.3). Using modified measurement method for Pauwels’ angle using central line of the shaft as a guideline, the angle of a conventional coronal CT image was measured. CT images were imported into Mimics® software. The scanning plane was then reformatted parallel to the neck axis to eliminate projection error of injured limb. Measured angles were classified into three types (I<30°; II, 30–50°; and III>50°) and differences were analyzed.

Results

Average Pauwels’ angle was 52.9° (range: 28.6–68.3°; SD: 9.9; type II, 17 cases; type III, 13 cases) for conventional CT images and 68.7° (range: 29.8–91.2°; SD: 13.4; type II, 1 cases; type III, 29 cases) for reformatted CT images. Difference between these two measurements on average was 15.7° (range: 1.2–34.9°; SD: 7.3).

Conclusions

Reformatting CT scanning plane by manipulating the proximal fragment to be parallel with the neck axis of the distal neck-shaft fragment is a convenient and reliable technique for eliminating the projection error of measuring Pauwels’ angle in the femur neck fractures.

Level of evidence

IV, cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Femur neck fracture, Young adult, Pauwels angle, Projection error


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 4

P. 607-611 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Poor results of functional treatment of Garden-1 femoral neck fracture in dependent patients
  • Roger Erivan, Marion Soleihavoup, Guillaume Villatte, Daniel Perez Prieto, Stéphane Descamps, Stéphane Boisgard
| Article suivant Article suivant
  • Prospective assessment of trochanteric fracture managed by intramedullary nailing with controlled and limited blade back-out
  • Manuela Barla, François Egrise, Bogdan Zaharia, Camille Bauer, Jauffrey Parot, Didier Mainard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.