S'abonner

Heart Rate Determination in Newborns at Risk for Resuscitation in a Low-Resource Setting: A Randomized Controlled Trial - 20/05/20

Doi : 10.1016/j.jpeds.2020.02.026 
Francesco Cavallin, MS 1, Maria Sofia Cori, MD 2, Senait Negash, MD 3, Gaetano Azzimonti, MD 4, Giovanni Vento, MD 2, Giovanni Putoto, MD 5, Daniele Trevisanuto, MD 6,
1 Independent statistician, Solagna, Italy 
2 Department of Woman and Child Health, Università Cattolica del Sacro Cuore, Roma, Italy 
3 Department of Pediatrics, St. Luke Catholic Hospital, Wolisso, Ethiopia 
4 Research Office, Doctors with Africa CUAMM, Wolisso, Ethiopia 
5 Research Office, Doctors with Africa CUAMM, Padova, Italy 
6 Department of Woman's and Child's Health, University of Padova, Padova, Italy 

Reprint requests: Daniele Trevisanuto, MD, Department of Woman's and Child's Health, University of Padova, Via Giustiniani 3, 35128, Padova, Italy.Department of Woman's and Child's HealthUniversity of PadovaVia Giustiniani 3Padova35128Italy

Abstract

Objective

To compare 2 different methods (auscultation with a stethoscope and umbilical cord palpation) of heart rate (HR) estimation in newborns at risk for resuscitation in a low-resource setting.

Study design

Sixty newborns at risk for resuscitation born at the St. Luke Catholic Hospital in Wolisso (Ethiopia) were randomized to HR assessment by auscultation using a stethoscope or umbilical cord palpation. HR was assessed at 60, 90, 120 seconds, and 5 minutes of life. The primary outcome was the agreement of HR obtained by auscultation or palpation compared with the HR determined by electrocardiogram.

Results

Mean difference between auscultation using a stethoscope and electrocardiogram was −13 bpm, −4 bpm, −6 bpm, and −10 bpm at 60, 90, 120 seconds, and at 5 minutes of life. Mean difference between palpation and electrocardiogram of was −20 bpm, −25 bpm, −23 bpm, and −31 bpm at 60, 90, 120 seconds, and at 5 minutes of life. The magnitude of the difference between auscultation and electrocardiogram was lower than that between palpation and electrocardiogram over time (P = .007). HR range was correctly identified in 14 out of 16 measurements (87%) with HR <100 bpm.

Conclusion

HR assessment by auscultation was more accurate compared with cord palpation, but both may provide adequate clinical information to healthcare providers in terms of HR ranges. The clinical advantage of providing a stethoscope in low-resource settings remains to be established.

Trial registration

ClinicalTrials.gov: NCT03854435.

Le texte complet de cet article est disponible en PDF.

Keywords : infant newborn, heart rate, low-resource setting, resuscitation

Abbreviations : BPM, ECG, HR


Plan


 Supported by a grant of the Italian Episcopal Conference. The authors declare no conflicts of interest.


© 2020  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 221

P. 88 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Early Electroencephalogram Background Could Guide Tailored Duration of Monitoring for Neonatal Encephalopathy Treated with Therapeutic Hypothermia
  • Giulia M. Benedetti, Rebecca J. Vartanian, Harlan McCaffery, Renée A. Shellhaas
| Article suivant Article suivant
  • A Bidirectional Analysis of Feeding Practices and Eating Behaviors in Parent/Child Dyads from Low-Income and Minority Households
  • Jerica M. Berge, Jonathan Miller, Sara Veblen-Mortenson, Alicia Kunin-Batson, Nancy E. Sherwood, Simone A. French

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.