Corresponding author at: Universitätsklinik für Notfallmedizin, Medizinische Universität Wien, Allgemeines Krankenhaus der Stadt Wien, Währinger Gürtel 18-20/6D, 1090 Wien, Austria.Universitätsklinik für NotfallmedizinMedizinische Universität WienAllgemeines Krankenhaus der Stadt WienWähringer Gürtel 18-20/6DWien1090Austria

Abstract

Objective

This work investigates the potential of photoplethysmography (PPG) to detect a spontaneous pulse from the finger, nose or ear in order to support pulse checks during cardiopulmonary resuscitation (CPR).

Methods

In a prospective single-center cross-sectional study, PPG signals were acquired from cardiac arrest victims who underwent CPR. The PPG signals were analyzed and compared to arterial blood pressure (ABP) signals as a reference during three distranaisco; Date: 2/2/2020; Time:18:44:23inct phases of CPR: compression pauses, on-going compressions and at very low arterial blood pressure. Data analysis was based on a qualitative subjective visual description of similarities of the frequency content of PPG and ABP waveform.

Results

In 9 patients PPG waveforms corresponded to ABP waveforms during normal blood pressures. During ABP in the clinically challenging range of 60 to 90 mmHg and during chest compressions and pauses, PPG continued to resemble ABP, as both signals showed similar frequency components as a result of chest compressions as well as cardiac activity. Altogether 1199 s of PPG data in compression pauses were expected to show a spontaneous pulse, of which 732 s (61%) of data were artifact-free and showed the spontaneous pulse as visible in the ABP.

Conclusions

PPG signals at all investigated sites can indicate pulse presence at the moment the heart resumes beating as verified via the ABP signal. Therefore, PPG may provide decision support during CPR, especially related to preventing and shortening interruptions for unnecessary pulse checks. This could have impact on CPR outcome and should further be investigated.

Le texte complet de cet article est disponible en PDF.

Abbreviations : ABP, CA, CPR, ECG, ETCO2, IQR, PEA, PPG, ROSC, VF

Keywords : Cardiopulmonary resuscitation, Signal transduction, Photoplethysmography, Cardiac arrest, Monitoring, Pulse


Plan


© 2019  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 38 - N° 3

P. 526-533 - mars 2020 Retour au numéro
Article précédent Article précédent
  • Can the “important brain injury criteria” predict neurosurgical intervention in mild traumatic brain injury? A validation study
  • Justine Lessard, Alexis Cournoyer, Jean-Marc Chauny, Éric Piette, Jean Paquet, Raoul Daoust
| Article suivant Article suivant
  • Involuntary patient length-of-stay at a suburban emergency department
  • Michael J. Maniaci, Christian Lachner, Tyler F. Vadeboncoeur, David O. Hodge, Nancy L. Dawson, Teresa A. Rummans, Archana Roy, M. Caroline Burton

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.