S'abonner

Reliability of cephalograms derived of cone beam computed tomography versus lateral cephalograms to estimate cervical vertebrae maturity in a Peruvian population: A retrospective study - 11/05/20

Doi : 10.1016/j.ortho.2020.01.001 
Gustavo Echevarría-Sánchez 1, Luis Ernesto Arriola-Guillén 2, , Violeta Malpartida-Carrillo 1, Pedro Luis Tinedo-López 1, Ricardo Palti-Menendez 3, Maria Eugenia Guerrero 1, 4
1 Universidad Científica del Sur, Division of Oral Implantology, School of Dentistry, Lima, Peru 
2 Universidad Científica del Sur, School of Dentistry, Division of Orthodontics and Division of Oral and Maxillofacial Radiology, Lima, Peru 
3 IDM Center, Private Practice, Lima, Peru 
4 Universidad Nacional Mayor de San Marcos, Faculty of Dentistry, Medico Surgical Department, Lima, Peru 

Luis Ernesto Arriola-Guillén, Universidad Científica del Sur, Faculty of Dentistry, Division of Orthodontics, Calle Los Girasoles 194, Surco, Lima, Peru.Universidad Científica del Sur, Faculty of Dentistry, Division of OrthodonticsCalle Los Girasoles 194, SurcoLimaPeru

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 4
Vidéos 0
Autres 0

Summary

Objective

Cone beam computed tomography (CBCT) images can be useful for estimating cervical vertebrae maturity (CVM). The aim of this study was to evaluate the reliability of cephalograms derived from CBCT versus lateral cephalograms (LC) to estimate the CVM in a Peruvian population.

Material and methods

The sample evaluated consisted of 40 cephalograms derived from CBCT and 40 LC images from individuals aged 10–19 years. One trained and calibrated observer (Kappa scores0.90) interpreted the CBCT and LC images twice. Intra-observer reliability of each maturation stage on CBCT sagittal slices and LC images were analysed using the weighted kappa statistics (α=0.05). Comparison of CVM stages between CBCT slices and LC images were analysed by the Spearman rank correlation coefficient, p<0.05.

Results

The weighted kappa test showed almost perfect intra-observer agreement for the CVM stages using the CBCT sagittal slices (0.873). Considering the LC images, the weighted kappa test showed almost perfect intra-observer agreement too (0.937). In both intra-observer agreement, the difference was limited to one maturation stage of the CVM method. The first and second intra-observer agreement for the CVM stages between the CBCT sagittal slices and LC images were almost perfect (0.937 and 0.874). High correlation values at the first (0.975) and second (0.976) intra-observer agreement for the CVM stages between CBCT sagittal slices and LC images were also found.

Conclusion

CBCT is a reliable method for CVM assessment and can be used as an alternative method for this purpose. The orthodontists might use the CBCT scans as a valuable tool for CVM method estimation.

Le texte complet de cet article est disponible en PDF.

Keywords : Reliability, Cervical vertebrae maturation, Cephalometry, Cone-beam CT


Plan


© 2020  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 18 - N° 2

P. 258-265 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Assessment of the cortical bone thickness by CT-scan and its association with orthodontic implant position in a young adult Eastern Mediterranean population: A cross sectional study
  • Nada Nashee Al-Hafidh, Ali R. Al-Khatib, Nashee Nafi Al-Hafidh
| Article suivant Article suivant
  • CBCT assessment of posterior cranial base and surrounding structures in orthodontically treated adolescents
  • Kris Currie, Heesoo Oh, Carlos Flores-Mir, Manuel Lagravère

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.